6 English50 20015010040 2007040.2(MAX)(MIN)53210.5INPUTSENSITIVITY(V)B.R.FFREQUENCY(Hz)LPFFREQUENCY(Hz)-6dBBRF-12dBOFFPHASE1800AMP CONTONOFFISFONOFFISF FREQUENCY25Hz15HzLPF OPERATION50 Hz70 Hz100 Hz150 Hz200 Hz-2030-16-12-8-4050 6040 100 200 300 400 1K (Hz)VOLTFANCURRTEMPDisplay modeYou can set up the display items as follows:1 Enter Menu modePress the [MENU] button."VOLT"/"CURR"/"TEMP"/"FAN" is displayed.2 Select a display itemPress the [2] or [3] button.The display items are switched in the following sequence.Display Information"VOLT" Indicates the source voltage (V)."CURR" Indicates the current consumption (A)."TEMP" Indicates the internal temperature (°F/°C)."FAN" Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF".3 Exit Menu modePress the [MENU] button for at least 1 second.NOTEWhen the internal temperature is -22°F/-30°C or less, "-22F"/"-30C" isdisplayed.Separate Amp ControlYou can control sounds using the Amplifier Control function of the unit.1 Enter Menu modePress the [MENU] button.2 Select the Menu itemPress the [MENU] button.The setup items are displayed approximately 1 second first, then the setvalues are displayed.3 Adjust the Menu itemPress the [2] or [3] button.The setup items and set values are switched as follows.Display Range Adjustment Item"VOLT"/"CURR"/"TEMP"/"FAN" For the operation method refer to "BASS" 60/80/100/200 (Hz) Bass Center Frequency"BA G" B–15 — B+15 (dB) Bass level"BA Q" Q1.00/Q1.25/Q1.50/Q2.00 Bass Q Factor"EXT" ON/OFF When the bass extend is set to ON, low frequency response isextended by 20%."VOL" –20 — 0 (dB) Volume offset"TEMP" FAHR (Fahrenheit) orCELS (Centigrade)The Fahrenheit or Centigrade temperature unit can be selectedfor the Display mode."DEFA" For the operation method refer to "AMP" 0 — 7 The ID Number you have assigned is displayed.4 Exit Menu modePress the [MENU] button for at least 1 second.NOTEWhen you hold down the [3] button 3 or more seconds during ID numberdisplay ("AMP"), message "MEMO" is displayed and you can register the valuesyou have set with the Amplifier Control. To call the Amplifier Control’s values,hold down the [2] button 3 or more seconds during ID number display("AMP"). Then, you can recall the value when message "LOAD" is displayed.DefaultResets all values you have set to the initial (default) values.1 Enter Menu modePress the [MENU] button.2 Select Default modePress the [MENU] button.Select the "DEFA" display.3 Resets the value to its defaultPress the [3] button for at least 2 seconds.Message "----" is displayed, and the value is initialized.4 Exit Menu modePress the [MENU] button for at least 1 second.NOTEVolume offset value can not be initialized.Display DemonstrationThe "VOLT"/"CURR"/"TEMP"/"FAN" items are displayed repeatedly.Press the [MENU] button for at least 2 seconds.The indicator flashes in the Demonstration mode.Canceling the Demonstration modePress any button to cancel the Demonstration mode.MENU2 / 3IndicatorAmplifier Control System