NX-22049ADJUSTMENT (K TYPE)ItemCondition Measurement Adjustment Specifications /RemarksPanel tuning mode PC test mode Test-equipment Unit Terminal Unit Parts Method12. CW IDDeviation*4[NXDNVeryNarrow]1) Adj item: [CWID]Adjust: [✳✳✳✳]Deviation meterLPF: 15kHzHPF: OFFPTT: ONPress [B] key tostore the adjust-ment value.1) Adj item: [CW IDDeviation (NXDNVery Narrow)]Deviation meterLPF: 15kHzHPF: OFFPTT: Press[Transmit] button.Press [Apply] but-ton to store theadjustment value.DeviationmeterOscilloscopePanel ANT Panel [Paneltuningmode]Selector[PC testmode][ ],[ ]Write the value asfollowings.376 (Referencevalue)1.00kHz±0.10kHz*4: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 50.13. BatteryWarningLevelwriting1) Adj item: [BATT]Adjust: [✳✳✳]PTT: ON1) Adj item: [BatteryWarning Level]PTT: Press[Transmit] button.Power meterDVMPanel ANTBATTterminalPress the PTTswitch or [Transmit]button on the PCwindow.Apply 6.20V tobattery terminal.Confirm that onepre-determined nu-meric in the range 1to 256 appears.[Panel tuning mode]Press [B] key tostore the adjust-ment value.[PC test mode]Press [Apply] but-ton to store theadjustment value.14. BatteryWarningLevelcheck[Panel test mode]1) CH-Sig: 1-1BATT terminalvoltage: 6.0V whiletransmitting1) Test ChannelChannel: 1Test SignalingMode: AnalogSignaling: 1BATT terminalvoltage: 6.0V whiletransmittingCheck The transceivercan transmit withcausing the LED toblink.