NX-32070ADJUSTMENT (E TYPE)■ Necessary Deviation adjustment item for each signaling and modeThe following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following example. In thecase of the signaling “QT (Wide 5k)”, this signaling is composed of three elements [Balance, Maximum Deviation (Analog Wide 5k) and QT Deviation(Wide 5k)]. Please adjust Balance and Maximum Deviation (Analog Wide 5k) before adjusting QT Deviation (Wide 5k).Mode Signaling Necessary adjustment and orderWide 5k Wide 4k Narrow Very NarrowAnalogAudioStep 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 5k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 4k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Narrow)-QTStep 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 5k)Step 3. QT Deviation (Wide 5k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 4k)Step 3. QT Deviation (Wide 4k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Narrow)Step 3. QT Deviation (Narrow)-DQTStep 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 5k)Step 3. DQT Deviation(Wide 5k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 4k)Step 3. DQT Deviation(Wide 4k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Narrow)Step 3. DQT Deviation (Narrow)-LTRStep 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 5k)Step 3. LTR Deviation(Wide 5k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 4k)Step 3. LTR Deviation(Wide 4k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Narrow)Step 3. LTR Deviation (Narrow)-DTMFStep 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 5k)Step 3. DTMF Deviation(Wide 5k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 4k)Step 3. DTMF Deviation(Wide 4k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Narrow)Step 3. DTMF Deviation(Narrow)-5TONEStep 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 5k)Step 3. Single Tone Deviation(Analog Wide 5k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 4k)Step 3. Single Tone Deviation(Analog Wide 4k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Narrow)Step 3. Single Tone Deviation(Analog Narrow)-MSK(FleetSync)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 5k)Step 3. MSK Deviation(Analog Wide 5k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Wide 4k)Step 3. MSK Deviation(Analog Wide 4k)Step 1. Balance adjustStep 2. Maximum Deviation(Analog Narrow)Step 3. MSK Deviation(Analog Narrow)-NXDNAudio -Step 1. Balance adjustStep 2. Maximum Deviation(NXDN Narrow)Step 1. Balance adjustStep 2. Maximum Deviation(NXDN Very Narrow)CW ID - -Step 1. Balance adjustStep 2. Maximun Deviation(Analog Narrow)Step 3. CW ID Deviation(NXDN Very Narrow)• Balance is common with all the above deviation adjustments. If Balance (Transmitter Section 3) has already adjusted, please skip Step 1 and adjustfrom Step 2.• Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) is common with all the analog signaling deviations and CWID Deviation (NXDN Very Narrow).If Balance and Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) (Transmitter Section 5) have already adjusted, please skip Step 2 and adjustfrom Step 3.