NX-720(G)/72066-4. FunctionIf you press the [ ] key while “FIRM PRG” is displayed,the checksum is calculated, and a result is displayed.If youpress the [ ] key again while the checksum is displayed,“FIRM PRG” is redisplayed.Note:• This mode cannot be entered if the Firmware Program-ming mode is set to Disable in the Programming soft-ware.• Normally, write in the high-speed mode.7. Clone ModeProgramming data can be transferred from one trans-ceiver to another by connecting them via their modularmicrophone jacks. The operation is as follows (the transmittransceiver is the source and the receive transceiver is a tar-get). Clone mode should be enabled.The following data cannot be cloned.• Tuning data• Embedded massage with password• Model name data• ESN (Electronic Serial Number) data• My ID for 5-toneNote :The following data can be cloned.• Fleet (own)/ID (own) for FleetSync• Unit ID (own) for NXDN• ID (own) for MDC-12001. Turn the source transceiver power ON with the [ ] keyheld down (1 second), “CLONE MODE” is displayed onthe LCD.2. Power on the target transceiver.3. Connect the cloning cable (No. E30-3382-05) to the mod-ular microphone jacks on the source and target.4. Press the [ ] key on the source transceiver.The data of the source is sent to the target. While thesource is sending data, red LED blinked. While the targetis receiving the data, “PROGRAM” is displayed and greenLED blinked. When cloning of data is completed, thesource displays “END”, and the source red LED turnedoff, and the target automatically operates in the Usermode. The target can then be operated by the same pro-gram as the source.5. The other target can be continuously cloned. Carry outthe operation in step 2 to 4.7-1. How to enter the data passwordIf the read authorization password is set in the optionalfeature menu, you must enter the password (Source trans-ceiver) to activate a clone mode.You can use 0~9 to configure the password. The maxi-mum length of the password is 6 digits.1. [ ]+Power ON.2. “CLONE LOCK” is displayed on the LCD.3. If the [ ] and [ ] keys is pressed while “CLONE LOCK” isdisplayed, numbers (0 to 9) are displayed flashing. Whenyou press the [ ] key, the currently selected number isdetermined. If you press the [ ] key after entering thepassword in this procedure, “CLONE MODE” is displayedif the entered password is correct. If the password is in-correct, “CLONE LOCK” is redisplayed.Cloning cable(E30-3382-05)Fig. 27-2. Flow chart (Source transceiver)Press [ ] key + Power ON for 1 secondIspassword*set?* ReadAuthorizationpasswordShows CLONE LOCKYesYes[ ]NoNoClone modeEnter passwordStart the clone functionIs enteredpasswordcorrect?8. Firmware Version InformationPress and hold the [ ] key while turning the transceiverpower ON and then keep pressing and holding the [ ] key,the fi rmware version information appears on the LCD.REALIGNMENT