NX-800/800H82. Horn Alert/P.A. Relay Unit (KAP-2: Option)The Horn alert (max. 2A drive), Public address and Exter-nal speaker function are enabled by installing the KAP-2 inthe transceiver.2-1. Installing the KAP-2 unit in the transceiver(The kit A is not used in the KAP-2 accessories)1. Remove the cabinet, top packing and shielding plate ofthe transceiver.2. Set the KAP-2 relay unit jumper pins according to thepurpose of use.3. Remove the 6-pin jumper connector inserted in the TX-RX unit (A/2) connector (CN705). ( q )4. Insert one side of the lead wire with connector(E37-1114-05) into the relay unit connector (CN3) ( w )and the other side into the TX-RX unit (A/2) connector(CN705) ( e ).5. Place the relay unit at the position shown in Figure 2-2and secure it to the chassis with a screw.6. Remove the cap on the rear of the chassis by pushing itfrom the inside with your fi nger. ( r )7. Pass the 6-pin connector of the cable (E37-1113-15)through the chassis hole ( t ) and insert the bush intothe chassis hole.8. Rotate the bush of the cable 90 degrees counterclock-wise as viewed from the rear of the chassis. ( y )9. Insert the 6-pin connector of the cable into the connector(CN2) of the KAP-2 relay unit. ( u )Note: You must setup using the KPG-111D.INSTALLATIONCN705:CN705CN3E37-1114-05@.;CN2 >=E37-1113-15BFIg. 2-1 FIg. 2-2 FIg. 2-3FIg. 2-4