TK-231750ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifi cations / RemarksTest-equipment Unit Terminal Unit Parts Method2. OpenSquelch(5) [Wide]1) TEST CH: Center, High(2 points)SSG otuput: –121dBm(0.20μV)SSG MOD: 3.0kHz2) TEST CH: Low (1 point)SSG otuput: –121dBm(0.20μV)SSG MOD: 3.0kHzSSGDVMOscilloscopeANT FPU Press [Start](Auto tuning)(5) [Narrow] 3) TEST CH: Center, High(2 points)SSG otuput: –120dBm(0.22μV)SSG MOD: 1.5kHz4) TEST CH: Low (1 point)SSG otuput: –120dBm(0.22μV)SSG MOD: 1.5kHz3. TightSquelch[Wide]1) TEST CH: Center, High(2 points)SSG otuput: –116dBm(0.35μV)SSG MOD: 3.0kHz2) TEST CH: Low (1 point)SSG otuput: –116dBm(0.35μV)SSG MOD: 3.0kHz[Narrow] 3) TEST CH: Center, High(2 points)SSG otuput: –115dBm(0.40μV)SSG MOD: 1.5kHz2) TEST CH: Low (1 point)SSG otuput: –115dBm(0.40μV)SSG MOD: 1.5kHz4. Low RSSI[Wide]1) TEST CH: Center, Low, High(3 points)SSG otuput: –120dBm(0.22μV)SSG MOD: 3.0kHz[Narrow] 2) TEST CH: Center, Low, High(3 points)SSG otuput: –120dBm(0.22μV)SSG MOD: 1.5kHz5. High RSSI[Wide]1) TEST CH: Center, Low, High(3 points)SSG otuput: –80dBm(22.4μV)SSG MOD: 3.0kHz[Narrow] 2) TEST CH: Center, Low, High(3 points)SSG otuput: –80dBm(22.4μV)SSG MOD: 1.5kHz