TK-3160286.VOX 10 TEST CH:Center Power meter ProgrammingWriting AG:1KHz/4.0mV Dev meter Software:KPG-82D7.DQT TCXO TEST CH:Center Oscilloscope ANT Programming WriteBalance (Wide/Narrow) AG Software:KPG-82DWriting AF VTVM[Wide] 70 hex[Narrow] 40 hex8. DQT VCO TEST CH: Center Make theBalance Adjust Low demodulation[Wide] High wave intoLPF:3kHz square wavesHPF:OFFPTT:ON[Narrow] TEST CH:CenterPTT:ON9. QT Deviation TEST CH: Center 0.8kHz ±40HzAdjust Low[Wide] HighLPF:3kHzHPF:OFFPTT:ON[Narrow] TEST CH: Center 0.4kHz ±40HzPTT:ON10. DQT Deviation TEST CH: Center 0.75kHz ±40HzAdjust Low[Wide] HighLPF:3kHzHPF:OFFPTT:ON[Narrow] TEST CH:Center 0.35kHz ±40HzPTT:ON11. Tone Deviation TEST CH:Center 3.0kHz ±100HzAdjust LPF:15kHz[Wide] HPF:OFFPTT:ON[Narrow] TEST CH:Center 1.5kHz ±100HzPTT:ON12.DTME Deviation TEST CH:Center 3.0kHz ±100HzAdjust LPF:15kHz[Wide] HPF:OFFPTT:ON[Narrow] TEST CH:Center 1.5kHz ±100HzPTT:ON13.MSK Deviation TEST CH: Center 3.0kHz ±100HzAdjust Low[Wide] HighLPF:3kHzHPF:OFFPTT:ON[Narrow] TEST CH:Center 1.5kHz ±100HzPTT:ON14 .BATT BATT terminal voltage:5.9V Power meter ANT Write BATT terminalDetection PTT:ON DVM BATT terminal voltage:5.9VWritingADJUSTMENTItem Condition Measurement Adjustment Specifications/Test equipment Terminal Parts Method Remark