TK-317021Item ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal PartsUnit MethodADJUSTMENT4. Low RSSI 1) Adj item : [LRSSI] SSG Panel ANT Panel Selector After input signaladjust Adjust : [✳✳✳.] knob from SSG, press [B]• Narrow SSG output : –118dBm (0.28μV) AF VTVM SP/MIC key. That numeric(MOD : 1kHz/± 1.5kHz) Oscilloscope will be stored inmemory.2) Adj item : [L.RSSI] →[L.R.S.SI] → [L.R.S.S.I.]Adjust : [✳✳✳.]5. Squelch 1) Adj item : [SQLT_] After input signal After adjusting SQL, check(Tight) Adjust : [✳✳✳.] from SSG, press [B] SQL open/close.adjust SSG output : –113dBm (0.5μV) key. That numeric SSG –111dBm : Open• Narrow (MOD : 1kHz/± 1.5kHz) will be stored in SSG OFF : Closememory.• Wide 4k 2) Adj item : [SQLT_]Adjust : [✳✳.✳.]SSG output : –114dBm (0.45μV)(MOD : 1kHz/± 2.4kHz)• Wide 5k 3) Adj item : [SQLT_]Adjust : [✳✳✳]SSG output : –114dBm (0.45μV)(MOD : 1kHz/± 3.0kHz)6. High RSSI 1) Adj item : [HRSSI] After input signaladjust Adjust : [✳✳✳.] from SSG, press [B]• Narrow SSG output : –70dBm (70.8μV) key. That numeric(MOD : 1kHz/± 1.5kHz) will be stored inmemory.2) Adj item : [H.RSSI] →[H.R.S.SI] → [H.R.S.S.I.]Adjust : [✳✳✳.]TC502TC501ANTCVTX-RX unit (A/4)Foil sideAdjustment Points