TK-3200L171.Setting 1) BATT terminal voltage:7.5V2) SSG standard modulation[Wide] MOD:1kHz,DEV:3kHz[Narrow] MOD:1kHz,DEV:1.5kHz2.VCO lock 1) CH:High Power meter ANT TC2 2.5V ±0.1Vvoltage RX 2) CH:Low DVM CV Check 0.6V or more3.VCO lock 3) CH:High TC1 3.0V ±0.1Vvoltage PTT:ONTX 4) CH:Low Check 0.6V or morePTT:ONCommon SectionItem Condition Measurement Adjustment Specifications/Test equipment Terminal Parts Method Remark1.Frequency 1) CH:High Frequency counter ANT VR1 High frequency Note: After replacingAdjust 2) PTT:ON ±50Hz the TCXO (X1) alignfrequency.2.High power TEST CH: Low Power meter Programming 2.0W ±0.1WAdjust Low’ Ammeter Software:KPG-88D 1.3 A or lessCenterHigh’High(5 points)BATT terminal voltage:7.5VPTT:ON3.Low power TEST CH: Low 1.0W ±0.1WAdjust Low’ 1.0 A or lessCenterHigh’High(5 points)BATT terminal voltage:7.5VPTT:ON4. DQT TEST CH: Center Power meter Make thebalance Adjust Low Deviation meter demodulation[Wide] High Oscilloscope wave into(3 points) AG square waves.LPF:3kHz AF VTVMHPF:OFFPTT:ON[Narrow] TEST CH:CenterPTT:ONTransmitter SectionItem Condition Measurement Adjustment Specifications/Test equipment Terminal Parts Method RemarkADJUSTMENT