28TK-8102Test Equipment Required for AlignmentTest Equipment Major Specifications1. Standard Signal Generator Frequency Range 400 to 520MHz(SSG) Modulation Frequency modulation and external modulationOutput –127dBm/0.1μV to greater than –7dBm/100mV2. Power Meter Input Impedance 50ΩOperation Frequency 400 to 520MHz or moreMeasurement Capability Vicinity of 100W3. Deviation Meter Frequency Range 400 to 520MHz4. Digital Volt Meter Measuring Range 1 to 20V␣ DC(DVM) Accuracy High input impedance for minimum circuit loading5. Oscilloscope DC through 30MHz6. High Sensitivity Frequency Range 10Hz to 1000MHzFrequency Counter Frequency Stability 0.2ppm or less7. Ammeter 20A8. AF␣ Volt Meter Frequency Range 50Hz to 10kHz(AF␣ VTVM) Voltage Range 1mV to 3V9. Audio Generator (AG) Frequency Range 20Hz to 20kHz or moreOutput 0 to 1V10. Distortion Meter Capability 3% or less at 1kHzInput Level 50mV to 10Vrms11. 4Ω Dummy Load Approx. 4Ω, 10W or more12. Regulated Power Supply 13.6V, approx. 20A (adjustable from 9 to 17V)Useful if ammeter requipped13. Spectrum Analyzer Center frequency 50KHz to 600MHz14. Tracking Generator Output Voltage 100mV or moreADJUSTMENTLead wire +MIC Shield wire –18Tuning cable (E30-3383-05)Adapter cable (E30-3383-05) is required forinjecting an audio if PC tuning is used.See "PC Mode" section for the connection.MIC connector(Front view)Test cable for microphone input (E30-3360-08)1 : BLC2 : PSB3 : E4 : PTT5 : ME6 : MIC7 : HOOK8 : CM