17TK-860G/(N)/862G/(N)REALIGNMENT10. Function Setting ModeAll channels can be set up together in the action mode byusing the panel keys.• Pressing [ ] when “SELF” is displayed, sets the functionsetting mode.• Select an item set using [ ] then change the selectionwith the [CH / ].• The data displayed using [D/A] is stored in the memoryand then proceeds to the next item.• Pressing [ ] proceeds to the next item without storing itin the memory.• Press [ ] to display “SELF” and return to reset (default)status.No. Function Choices Display RemarksOptional feature1 Power YES/NO PONT_YES Default : Yeson tone2 Control YES/NO CNTT_YES Default : Yestone3 Warning YES/NO WART_YES Default : Yestone4 Time out OFF, 15~600/ TOT__180 Default : 180stimer 15s step5 TOT OFF, 1~10/ TOTP_OFF Cannot be set whenpre-alert 1s step TOT is offtime Default : Off6 TOT OFF, 1~60/ TOTK_OFF Cannot be set whenrekey 1s step TOT is offtime Default : Off7 TOT OFF, 1~15/ TOTS_OFF Cannot be set whenreset 1s step TOT is offtime8 Squelch 0~9/1 step SQL__5__ Default : 5levelOthers9 Panel Enable PTM__ENA ←Defaulttest/ Not used for TK-762Gpanel Disable PTM__DIStuningmodeSelf programmingmodeFunction settingmodePower on tone yes/no[D/A]/[ ]Control tone yes/no[D/A]/[ ]Warning tone yes/no[D/A]/[ ][D/A]/[ ]Time out timerTOT pre-alert time[D/A]/[ ]TOT rekey time[D/A]/[ ]TOT reset time[D/A]/[ ][D/A]/[ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]Squelch level[D/A]/[ ][ ]Panel test/Panel tuning mode[ ]10-1. Flow Chart11. Memory Reset Mode (TK-860G only)You can clear all settings you made in self programmingmode, or you can return to the original display.• Press [SCN] while “SELF” is displayed will change thedisplay to “CANCEL”.• Press [CH / ] to change the display between “CAN-CEL” and “READY”.• When “READY” is displayed, pressing [SCN] will set alldata to default, and “CLEAR” will appear on the display.Press [SCN] again to display “SELF”.• When “CANCEL” is displayed, pressing [SCN] will cancelthe reset, and “SELF” will be displayed.