Page 6Find us at www.keysight.comPNA Family Network Analyzer Configurations (continued)1 For N522xA and N5241/42/49A, vector-noise-corrected measurements require an ECal for use as an impedance tuner. For N5244/45/47A with Option 029,an internal tuner is included. For calibration, Option 028 requires a power meter, and Option 029 requires either a power meter or a 346-series noise source(Keysight 346C or 346C-K01 recommended). All options require a power meter for measuring mixers and converters.2 Option 080 is required to configure an external source using External Device Configuration dialog.3 Option 082 is a subset of Option 083; therefore, they cannot be ordered together.4 A configurable test set is required for VMC measurements (to connect a reference mixer) or for SMC+Phase measurements using the comb-generator-basedcalibration. When ordered with N522xA-200, -210, -400 and -410, Option 083 adds phase and delay measurements only by using SMC+Phase with acalibration mixer.5 Option 087 can be ordered without N524xA-224 or N524xA-423, but may require external equipment such as a signal generator and a combiner. Refer topage 13 for more details.6 When ordering a test set, select an appropriate interface kit. Refer to page 22 Multiport Measurements section for more details.7 When configuring N524xA as a multiport analyzer using Option 551 and a multiport test set, the combiner feature of Option 224 or 423 is temporarilydisabled.When configuring N524xA as a standalone analyzer, the combiner feature is enabled.8 The Windows 7 upgrade kit for PNAs containing CPU version 6 is model N8983A. This upgrade kit contains a new solid state drive with all of the necessarysoftware installed. For units with older CPUs, order the N8984A with Option PC7. This upgrade kit contains a new solid state drive and a version 7 CPU. Foradding Option 090 to units with DSP version 4, add Option SP5 to the N8983A or N8984A order to get the DSP version 5.9 Option 093 is a subset of 094; therefore they cannot be ordered together.Application optionsTo add options to a product, order the corresponding item number (N52xxA-xxx).Measurement applicationFor PNA-XSeriesFor PNASeriesFor PNA-LSeries Additional InformationAutomatic fixture removal N524xA-007 N522xA-007 N523xA-007 Requires Windows 7 OS8Time-domain measurements N524xA-010 N522xA-010 N523xA-010Dynamic uncertainty for S-parametermeasurementsN524xA-015 N522xA-015 N523xA-015 Displays the measurement uncertainty dynamically (real-time) on themeasurement trace. Not available with N5231A,32A and 39ANoise figure measurements using standardreceivers1N524xA-028 N522xA-028 n/a Requires Option 080. For measuring frequency converters, requires Option082 or 083. Not available with N522xA-200, -210, -400 and -410Fully-corrected noise figuremeasurements1N524xA-029 n/a n/a Requires Option 080 and for N5241/42/49A, one of Options 219, 224, 419,423 or H85. For N5244/45/47A, requires Option 224 or 423. On N5247A, noisereceivers work up to 50 GHz only. For measuring frequency converters, requiresOption 082 or 083Frequency offset2 N524xA-080 N522xA-080 N523xA-080Scalar-calibrated converter measurements3 N524xA-082 N522xA-082 N523xA-082 Requires Option 080Vector- and scalar-calibrated convertermeasurements3, 4N524xA-083 N522xA-083 n/a Requires Option 080Embedded LO measurements N524xA-084 N522xA-084 n/a Requires Option 082 or Option 083. Also works with Options 028, 029, 086and 087Gain compression application N524xA-086 N522xA-086 n/a For measuring frequency converters, requires Option 082 or 083Intermodulation distortionapplication5N524xA-087 N522xA-087 n/a Requires Option 080 For measuring frequency converters, requires Option082 or 083. Not available with N522xA-200, -210, -400 and -410Source phase control N524xA-088 N522xA-088 n/a Not available with N522xA-200 and -210Differential and I/Q devices application N524xA-089 N522xA-089 n/a Requires Option 080 and 400, 401, 410, 417, or 419, and Windows 7 OS8Spectrum analyzer N524xA-090 N522xA-090 N523xA-090 Requires Option 080, Windows 7 OS, and DSP version 58. Test set and powerconfiguration option with receiver attenuators is recommendedExtended spectrum analyzer to 110 GHz9 N524xA-093 N522xA-093 n/a Requires Option 090. Not available with N5241/49A or N5221AExtended spectrum analyzer above 110 GHz9 N524xA-094 N522xA-094 n/a Requires Option 090. Not available with N5241/49A or N5221AIntegrated true-mode stimulus application N524xA-460 N522xA-460 n/a Requires one of Options 400, 401, 410, 417, 419 or 423N-port capabilities6 N524xA-5517 N522xA-551 N523xA-551 Not available with N522xA-200, -210, -400 and -410, and N523xA-200 and -400PNA-X SeriesN5249A 10 MHz to 8.5 GHzN5241A 10 MHz to 13.5 GHzN5242A 10 MHz to 26.5 GHzN5244A 10 MHz to 43.5 GHzN5245A 10 MHz to 50 GHzN5247A 10 MHz to 67 GHzPNA SeriesN5221A 10 MHz to 13.5 GHzN5222A 10 MHz to 26.5 GHzN5224A 10 MHz to 43.5 GHzN5225A 10 MHz to 50 GHzN5227A 10 MHz to 67 GHzPNA-L SeriesN5239A 300 kHz to 8.5 GHzN5231A 300 kHz to 13.5 GHzN5232A 300 kHz to 20 GHzN5234A 10 MHz to 43.5 GHzN5235A 10 MHz to 50 GHz