Classic Agricultural Animal Confinement Building HeatersOwner’s Manual • Classic111. Air diverters can be installed in the heater outletto provide direction to the heated air as it exits theheater. Installation options include installing thediverters in such a way as to broadly distribute the airin two 45 degree paths or to focus the air flow in one45 degree direction. See Fig. 1.2. The air diverters may require hand forming priorto installation. Make 90 degree bends utilizing theperforations provided. Diverters should have theshape as shown in Fig. 1.3. The air diverter’s tabs on each half will snap intothe blower outlet between the inside of the case as-sembly and the blower housing outlet. If the notchedtabs do not snap into the blower outlet, loosen (donot remove) the blower outlet screws. Doing thisprovides a gap into which you can insert the tabs.Retighten the screws after installation.FIG. 1(Typical installation allowing two directions of air movement.)TABSDIVERTERHALVESOUTLETSCREWSFORMEDOUTLET GUARDNOTCHES IN MOUNTING TABSAlternate Air Diverter Installations:1. Assemble according to the illustration and tightenall eyebolts securely. (See Fig. 2):FIG. 2EYEBOLTNUTFLAT WASHERCAGE NUTCHAINCASE TOP2. Be sure heater is securely fastened and is hanginglevel. (Check crosswise and lengthwise using alevel).3. See Fig. 3 for typical indoor installation. Whenusing in an animal confinement building, consider-ation must be given to making sure the heater islocated away from the livestock so that livestockcannot knock the heater, tear it loose from itsmounting, or damage the heater or its gas supplyline in any way. Make sure you observe and obeyminimum clearance distances to combustiblematerials as stated in the specification section ofthis owner’s manual and on the heater itself.FIG. 3NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IFCIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS,THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENTLINE NO SMALLER THAN VENT OPENING.VENT OF REGULATOR MUSTPOINT DOWN AND REGULATORMUST BE VENTED OUTDOORSMANUAL SHUT-OFF VALVECAN BE INSTALLED BEFORETHE REGULATOR, UNDERTHE EAVE OF THE BUILDING,OR AFTER THE REGULATORINSIDE THE BUILDING.OPTIONAL INDOORREGULATORMOUNTING LOCATIONGAS HOSETHERMOSTATCORDYOKEHEATERTHERMOSTAT 1 FT. / 0.3m 1 FT.0.3mBLACK PIPETHROUGH WALLVENT LINEWALL OUTLETPOWER CORDSEDIMENTTRAPWALLCHAIN OR CABLEAir Diverter InstallationInstructions(Must be ordered separately)Hanging Instructions