TERMOROSSELLA Plus DSA / Forno DSA – TERMONICOLETTA DSA / Forno DSA18 7197100 Rev.05 – EN1. TECHNICAL DATADefinition: thermoheating stove in compliance with EN 13240DSA TERMOROSSELLAPlusTERMOROSSELLAPlus FORNOTERMONICOLETTATERMONICOLETTAFORNOGlobal thermal power in kW 17.3 16.7 17.3 16.7Useful thermal power in kW 13.5 13.5 13.5 13.5Power yielded to the water in kW 10.5 10.5 10.5 10.5Power yielded to the environment in kW 3 3 3 3Hourly wood consumption in kg/h(wood with 20% humidity) 4 3.9 4 3.9Yield in % 78.2 81,1 78.2 81,1CO measured at 13% of oxygen in % 0.10 0.07 0.10 0.07Flue pipe diameter in mm 130 130 130 130Flue diameter in mm *5m 220x220Ø2204m 250x250Ø2505m 220x220Ø2204m 250x250Ø2505m 220x220Ø2204m 250x250Ø2505m 220x220Ø2204m 250x250Ø250Water content in the boiler in litres (L) 18.5 18.5 18.5 18.5Depression at the chimney in (mm H2O) 1.7 / 2 1.7 / 2 1.7 / 2 1.7 / 2Delivery and return connection diameters in gasinches 1”g F 1”g F 1”g F 1”g FExternal air intake section Ø in mm 200 200 200 200Flu gas emission in g/s – wood 13.5 14.7 13.5 14.7Flue gas temperature in the middle in °C - wood 270 214 270 214Optimal working temperature in °C 70 - 75 70 - 75 70 - 75 70 - 75Max. operating pressure in bar VEA1,5 – VEC3 VEA1,5 – VEC3 VEA1,5 - VEC3 VEA1,5 - VEC3Fireplace opening dimensions in mm (W x H) 355x245 345x245 355x245 345x245Fireplace body dimensions /fireplace headin mm (W x H x D) 307x245x345 307x318x345 307x245x345 307x318x345Stove dimensions in mm (W x H x D) - 330x300x370 - 330x300x370Type of grid mobile, flatThermoheating stove height in mm 915 1359 980 1423Thermoheating stove width in mm 559 559 587 587Thermoheating stove depth (with handles) in mm 533 533 575 575Weight in Kg 160 - 175 218 – 242 183 254Fire precaution safety distance Chapter 4∗∗∗∗ Diameter 200 mm to be used with flue not less than 6 mThe heating capacity of the rooms according to EN 13240 for buildings whose heat insulation does not correspondwith the requisites of the Regulation regarding heat insulation, is:(30 Kcal/h x m3) - favourable type of construction: 390 m³(40 Kcal/h x m3) - less favourable type of construction: 292 m³(50 Kcal/h x m3) - unfavourable type of construction: 233 m³With heat insulation suitable for the provisions regarding heat protection the heating volume is greater. Withtemporary heating, in the case of interruptions exceeding 8h, the heating capacity decreases by about 25%.