15MOUNTINGNote: Before permanently mounting ensure that the indoor weather station is able to receive WWVB signals from thedesired location. Also, extreme and sudden changes in temperature will decrease the accuracy of the indoor weather station,and changes in elevation will result with inaccurate weather forecasting for the next 12 to 24 hours. These changes willrequire a 12 to 24 hour wait before obtaining reliable data. To achieve a true temperature reading, avoid mounting wheredirect sunlight can reach the remote temperature/humidity sensor or indoor weather station. While the remotetemperature/humidity sensor is weather proof, avoid submersion in water or snow. We recommend that you mount theremote temperature/humidity sensor on an outside North-facing wall. The sending range is 300ft—obstacles such as walls,concrete, and large metal objects can reduce the range. Place both units in their desired location, and wait approximately 15minutes before permanently mounting to ensure that there is proper reception. The indoor weather station should display atemperature and humidity in the OUTDOOR LCD and wind speed (can be 0.0) in the WIND SPEED LCD within 4 minutesof setting up.I. THE REMOTE TEMPERATURE/HUMIDITY SENSORThe remote temperature/humidity sensor can be mounted in several ways:• With the use of screws• Using adhesive tape• Using nylon strapsA. MOUNTING WITH SCREWS1) Remove the mounting bracket from the remotetemperature/humidity sensor.2) Place the mounting bracket over the desired location.3) Through the two screw holes of the bracket, mark themounting surface with a pencil.4) Screw mounting bracket onto the mounting surface. Ensurethat the screws are tight against the bracket.5) Insert the remote temperature/humidity sensor into thebracket.B. MOUNTING WITH ADHESIVE TAPE1) With a nonabrasive solution, clean and dry the back of the mounting bracket and the mounting surfaceto ensure a secure hold. The mounting surface should be smooth and flat.2) Remove the protective strip from one side of the tape.3) Adhere the tape to the designated area on the back of the mounting bracket.4) Remove the protective strip from the other side of the tape.5) Position the remote temperature/humidity sensor in the desired location, ensuring that the indoorweather station can receive the signal.C. MOUNTING WITH NYLON STRAPS1) Remove the mounting bracket from the remotetemperature/humidity sensor.2) Place two nylon straps through the slots on the mounting bracket.3) Place the remote temperature/humidity sensor in your desiredmounting location.4) Fasten the two nylon straps securely around the mountinglocation.
PreviousNext |