EnglishDescriptionF ir e nz e - It a li aDisplay Operating Procedure9www.lamarzocco.com Version 1.3GB/5 - FB/80 Factory Level ParametersNominal Coffee Boiler TemperatureCoffee BoilersTemperatures• This parameter is set at the factory at a presetnominal temperature.• The set temperature of this parameter differs fromthe actual temperature of the water exiting the groupto the coffee.• The temperature of the boiler is measured at themost critical point in the boiler when temperaturefluctuation is the greatest.• The temperature of the water exiting the group headis held constant by means of the mass of the groupcasting. Even though the temperature of the boilermay vary a few degrees, the temperature of thewater exiting the group is constant.• To set the temperature of any espresso machine it isimportant to measure the temperature of the waterexiting the group.Password?????Press and hold the button on the group 1 keypad until the following is displayed(approximately 10 seconds):1LaMarzocco 09:30Enter the 5 digit factory password using buttons 1-5 on the group 1 keypad. Once accepted thefollowing appears:2Groups Number3 3 Press the button on the group 1 keypad until the following appears (two times):MODECoffee Boiler 1202.5°F 202.6°F4 Press the button to select the coffee boiler you wish to change temperature.Coffee BoilersTemperaturesENTERPress the or the button to change the temperature on the displayed boiler. Themeasured temperature appears on the left and the set temperature appears on the right side of thedisplay. Once the desired temperature is selected press the button to confirm the selection.5+ENTERRepeat procedure 5 for all subsequent boilers (if installed).6When finished, continue to the next parameter or press to exit programming mode.7 ONOFF