Configuration via Serial Mode or Telnet PortWiPort™ User Guide 43Table 5-5. Reserved Port NumbersPort Numbers Reserved for1 – 1024 Reserved9999 Telnet setup14000-14009 Reserved for Redirector30704 Reserved (77F0h)30718 Reserved (77FEh)Note: It is recommended to not use the reserved port numbers for thissetting as incorrect operation may result.Use Port 0 for the outgoing local port to change with each connection. The port rangeis 50,000 to 59,999. Each subsequent connection increments the number by 1 (itwraps back around to 50,000).Only use this automatic port increment feature to initiate a connection using TCP. Setthe port to a non-zero value when the unit is in a passive mode or when using UDPinstead of TCP.Connect ModeConnect Mode defines the unit’s connection method and its reaction to incomingconnections over the network. The current value is displayed in parentheses.ConnectMode (C0) ? _Enter Connect Mode options in hexadecimal notation:Table 5-6. Connect Mode OptionsConnect Mode Option 7 6 5 4 3 2 1 0a) Incoming ConnectionNever accept incoming 0 0 0Accept with modem_control_in Active 0 1 0Always Accept 1 1 0b) ResponseNothing (quiet) 0Character response (C=connect,D=disconnect, N=unreachable) 1c) Active StartupNo active startup 0 0 0 0With any character 0 0 0 1With modem_control_in Active 0 0 1 0With a specific start character 0 0 1 1