Configuration via Serial Mode or Telnet PortWiPort™ User Guide 36Figure 5-2. Setup Menu OptionsChange Setup:0 Server1 Channel 12 Channel 23 Email4 WLAN5 Expert6 Security7 Defaults8 Exit without save9 Save and exit Your choice ?5. Select an option on the menu by entering the number of the option in the Yourchoice ? field and pressing Enter.View the current configuration by pressing Enter from the Change Setup menu.To enter a value for a parameter, type the value and press Enter. To confirm acurrent value, press Enter (without inputted parameters).6. When finished, save the new configurations (9 Save and exit). The unit reboots.Serial Port AccessTo configure the unit through a serial connection:1. Connect a console terminal or PC running a terminal emulation program to yourunit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity,1 stop bit, no flow control.2. Reset the WiPort unit by cycling the unit's power (turning the power off and backon). Immediately upon resetting the device, enter three lowercase x characters(xxx).Note: The easiest way to enter Setup Mode is to hold down the x key atthe terminal (or emulation) while resetting the unit. This must be donewithin three seconds of resetting the WiPort.3. Upon connection, the following information displays:Figure 5-3. MAC AddressMAC address 00204AFFFF30Software version V6.0.0.0 (050214)Press Enter to go into Setup Mode4. To enter the Setup Mode, press Enter within 5 seconds.Note: Connection fails if Enter is not pressed within 5 seconds.The configuration settings display, followed by the setup menu options:Figure 5-4. Setup Menu OptionsChange Setup:0 Server1 Channel 12 Channel 23 Email4 WLAN5 Expert