24PEGASOEnglishPROBLEMS AND SOLUTIONSWSolutionCauseProblem• The apparatus doesn’t start• The equipment does not suck theproduct• No air from compressor• When pressing the trigger, thepressure lowers considerably• Lack of power;• Strong drops in network voltage;• On/Off switch disconnected;• Pressure sensor failure;• Breakdown of pressure transmitter;• The product is solidified insidethe pump;• Blocked compressed air;• The product is too dense;• Loose fittings;• Plugged gun;• Worn peristaltic pump hoses;• Solidified material in the gun;• Sensor is bad;• Check air system for leaks;• Compressor off;• Gun needle plugged;• Lines not connected;• Damaged hose;• Worn compressor;• The nozzle is too big or is worn;• The product is too dense;• Anomaly in the transducer.• Make sure the power line is connec-ted properly;• Check the extension cord;• Ensure the On/Off switch is on the“on” position and turn clockwise thepressure control knob;• Verify and replace it, if necessary;• Verify and replace it, if necessary;• Discharge the pressure in the circuitand turn the machine off. Dismantlethe peristaltic pump hose, clean it,and if necessary replace it;• Turn the compressor on; open thecompressed air pressure regulatoron the gun;• Add water to thin material.Use Material Thickness Gauge.• Check and retighten all fittings;• Relieve Pressure. Remove gun fromhose. Clean gun;• Replace the hoses;• Disassemble the gun and cleanthrough the hoses;• Replace;• Remove shroud and examine for airleaks;• Turn the compressor on;• Clean needle and retry;• Check all quick disconnect connec-tions to gun and hoses;• Replace hose;• Service compressor.Contact a qualified Graco ServiceCenter;• Replace it with a smaller one;• Dilute the product, if possible;• Replace it.