Page 15 Digital Display Wall Clock GuideNote: The long dimension of the mounting plate must be perpendicular to the ground to assure properalignment of wall clocks.See page 15, figure 4 for DDC2 details.See page 16, figure 5 for DDC4 details.DDC2 (Double Mount - Wall)» Remove the four phillips head screws from the left and the right end caps of the two DDC2 clocksand remove. Slide the lenses and circuit board assemblies out of the cases and set aside.» Place the two DDC2 clocks back to back and secure by inserting a #10 screw through the two keyholes and the two lower mounting holes using lock washers and nuts supplied with the mountingkit.» Attach the modified end caps to the end of the clocks that will be attached to the wall mount plateusing the original end cap screws.» Run the required wiring through the matching hole in the modified end cap.» Line the two posts from the mounting plate up with the two holes of the modified end caps. Insertthe chase nipples through the holes of the modified end caps and secure to the mounting plate witha 15/16" wrench.» Slide the circuit board assemblies in partially. Secure the required wiring and install the battery ifused.» Slide the circuit board assemblies in fully along with the lenses. Install the end caps and secureeach with its four screws.» Discard or store the two original end caps the modified end caps replaced.DDC2 casesmodified end caps#10 screws#10 lock washers#10 lock washers#10 hex nutsmounting platechase nipplesFigure 4