106. TECHNICAL DATABasic parameters:– analog output galvanicaly isolated:- current (max. range) - 20...20 mA- voltage (max. range) -10...10 V- load resistance of the current output £ 500 W- load resistance of the voltage output ≥ 500 W– conversion class1) 0.2– averaging time of the measurement ≥ 0.1 s– power input < 2 VA– warm-up time of the separator 10 min– response time of the separator ≥ 0.1 sRated operating conditions:– supply depending on theversion code 85...253 V a.c./d.c.20...85 V d.c., 20...65 V a.c.– frequency of the supplya.c. voltage 45...65 Hz– ambient temperature - 20...23...55°C– storage temperature - 25...85°C– related air humidity < 95% (inadmissiblecondensation of water vapour)– operating position anyAdditional errors:– from temperature changes 50% of class/10 KInput parameters:– resistance of voltage input [V] > 1 M W– resistance of current input [mA] 12 W ±1%Sustained overload:- voltage 1.2 Xn- current 1.1 Xn