en | 12 | VCX-32HD | Operation6.7 Decontamination1. Remove coolant filter cartridge from filter bowl.2. Reinstall bowl.3. Connect pickup tube/standpipe (P/N: 370 80283 00)to the drain/fill hose.4. Place pickup/standpipe in an approved wastecontainer.5. Connect air supply.6. Flip FILL SWITCH to ON.7. Open the FLOW CONTROL VALVE.8. The contaminated coolant will flow into the wastecontainer.9. When the flow stops, the VCX-32HD tank will beempty.10. Flip FILL SWITCH to OFF. Close FLOW CONTROLVALVE.11. Add the appropriate amount of water along withcoolant flush to a bucket/container and mix thesolution. If coolant flush is not available, use 3-4ounces of a low foaming liquid detergent.12. Place pickup/standpipe in the bucket of solution.13. Flip the DRAIN SWITCH to ON.14. Open both FLOW CONTROL and the DRAINCONTROL VALVE.15. VCX-32HD will pull the solution throughout all thelines and valves decontaminating as it flows.16. Once all the fluid has been introduced into themachine allow the machine to run for 1 minute. Thiswill clean the tank as air will be introduced into thetank from the bottom.17. Close both FLOW CONTROL and the DRAINCONTROL VALVE.18. Place the pickup/standpipe in an approved wastecontainer.19. Flip the FILL SWITCH to ON. Open FLOWCONTROL VALVE. When the flow stops, flip FILLSWTICH to OFF. Close FLOW CONTROL VALVE.20. Add the appropriate of clean water to a bucket andplace the pickup/stand pipe into the bucket.21. Flip the DRAIN switch to ON. Open both FLOWCONTROL and the DRAIN CONTROL VALVE.22. Once the appropriate of water have been introducedinto the machine allow the machine to run for 1minute. This will rinse the tank. Flip the DRAINSWITCH to OFF23. Close the DRAIN CONTROL VALVE.24. Place the pickup/standpipe in an approved wastecontainer.25. Flip the DRAIN SWITCH to ON. Open the FLOWCONTROL VALVE. This will rinse the fill circuit.26. When the flow stops flip the fill switch to OFF. Closethe FLOW CONTROL VALVE.27. Check for foam and contamination in container.28. Repeat rinse cycle until there is no foam orcontamination in rinse container. Repeat solutionflush if needed.29. Replace coolant filter cartridge; P/N: 026 80725 00.