Madell Technology Corporation TYR108C Manual
Madell Technology, Corporate Office, 1141 E Philadelphia Street, Ontario, CA 91761t. 877-670-9023 f. 909-418-6956Website: www.madelltech.com; Technical Service Email: info@madelltech.com6Madell Technology, Corp.with that specified for this machine, and connect reliably the grounding wire of the power plug of thismachine with the grounding device. It is also required that the power socket be grounded reliably,otherwise electric leakage from the equipment may occur (sparking may occur). If encountering thissituation, stop installation at once and check if the power socket is grounded reliably. If not, physicalinjury may occur.3.3.2 Starting the MachinePress the power switch of the reflow soldering machine, the display window PV will display thecurrent internal test temperature of the machine and the window SV will display the actual settemperature. After all are normal, press RUN button to do dry running once to check abnormality. If noabnormality is found, put prepared PCB onto the PCB bench. Press RUN button to start a solderingcycle, i.e. temperature rise, temperature keeping, second reflow, and cooling (cooling blower fan startsto operate); when the cooling is to end, the alarm system starts to operate, prompting us that asoldering cycle is completed. At this moment, open the drawer and remove the PCB with antistaticgloves put on. If soldering needs to continue, repeat the above steps.4. Setting of Temperature Curve4.1 Panel DescriptionAfter normal startup and entering standby mode, the current temperature is displayed in the [PV]window and PROG is displayed in the [SV] window.(1) [PV] measurement display window: displays parameter symbols at parameter settingstate and displays program segment symbols at program setting state;(2) [SV] set value display window: displays the set target values; displays output percentageat output monitoring state, and displays options or parameter values at parameter monitoringstate;(3) Indicator lamps: manual indicator lamp MAN: this lamp lights up at manual control stateuntil entering automatic state; self-adjusting indicator lamp AT (no this function in this machine):this lamp flashes at parameter self-adjusting state, and goes out after the adjustment iscompleted or released; control output indicator lamp OP1: when the output is contact or SSRdriving voltage, this lamp lights up at ON state, and goes out at OFF state; OP2: when the outputis current-voltage or phase shift trigger output, this lamp lights up; alarm indicator lamp AL1-AL2:this lamp lights up when an alarm is given;External setting indicator lamp RSV: this lamp lights up when the instrument is at externalsetting state and goes out when the instrument is at internal setting state;Communication indicator lamp COM: this lamp flashes when the instrument communicateswith the upper computer.(4) Help chart: displays measurement or output values or valve opening degrees inpercentage.(5) Operation keys: A. MANUAL/AUTOMATIC switchover key A/M: press this key for 2seconds at LEBELO mode, the instrument is switched over between MANUAL and AUTOMATIC,and press this key at parameter setting state, you can return to the upper level menu; B. Functionkey [ā]: you can press this key at initial LEVELO state for 2 seconds to enter mode selectionmenu, and press it for 2 seconds again to return to the initial LEVELO state; you can press thiskey at mode selection menu to enter parameter setting state; the screen moves forward once forevery key press until entering mode selection menu; this key also has the function to invoke |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine