Enrange CHTX Transmitter Instruction ManualDecember 2017Page 45 of 478 Troubleshooting8.1 General TroubleshootingProblem Error on Display CauseTransmitter shuts down duringnormal operationOff Activated Unit has been turned off by the operator.Machine Stop Machine stop has been pressed by theoperator.Inactivity TimeoutNo input has been activated on thetransmitter for the period of time set forthe inactivity timer.Low Battery Transmitter battery is too low.Drop Detected A drop of the transmitter has beendetected where it has struck an object.Long Drop Detected A freefall drop of the transmitter has beendetected.TILTTilt detection in the transmitter is enabledand the angle of the tilt is beyond theacceptable range.Key Switch Power Off The transmitter key switch input hasbeen turned off.Transmitter shuts down duringinitializationOn/Off Switch FAILAn error has been detected with the Off/On/Start switch during startup. Check theconnection between the switch and theboard.Estop FAILAn error has been detected with the E-stop switch during startup. Check theconnection between the switch and theboard.Motion X failedAn error has been detected with Motion Xduring startup where it is not centered.Return Motion X to the center positionand cycle power to the transmitter. Referto the system drawings to determine thelocation of the switch.Motion X dir failedAn error has been detected with Motion Xduring startup. Check the connectionbetween the input and the board. Referto the system drawings to determine thelocation of the switch.