- Introduction
- How an Inverter/Charger Works
- Standard Features and Benefi ts
- Figure 3, Top and Left Side Features
- Figure 4, Front and Back Side Features
- Battery Temperature Sensor
- Installation
- Figure 6, MMS1012 Model Basic Installation Diagram
- Figure 7, MMS1012-G Model Basic Installation Diagram
- Locating and Mounting the Inverter
- Figure 9, MMS1012 Model Inverter/Charger Dimensions
- Wiring Guidelines
- DC Wiring
- DC Overcurrent Protection
- DC Grounding
- DC Cable Connections
- Battery Bank Wiring
- DC Ground Wire
- AC Wiring
- AC Wiring Connections
- AC Input Wiring
- Figure 13, AC Wiring Connections (MMS1012 model)
- AC Output Wiring
- Functional Test
- Operation
- Standby Mode
- Figure 15, Automatic 4-Stage Charging Graph
- Figure 16, BTS Temperature to Charge Voltage Change
- Protection Circuitry Operation
- Inverter Start-up
- Factory Default Settings
- Table 6, Inverter/Charger Default Settings
- Maintenance and Troubleshooting
- Resetting the Inverter
- Table 7, Troubleshooting Guide
- Table 8, MMS Series Specifi cations
- Appendix A - Optional Equipment and Accessories
- Figure 18, Series Battery Wiring
- Series-Parallel Wiring
- Figure 21, Battery Bank Wiring Examples (12-volt)
- limited warranty
- How to Receive Repair Service
|
© 2010 Magnum Energy, Inc.Figure 3, Top and Left Side Features1. Inverter Status Indicator - this green LED illuminates to provideinformation on the inverter’s operation.2. Power Switch - momentary pushbutton switch that turns theinverter on or off.3. Negative DC Terminal (black) - the inverter’s connection to thenegative terminal on the battery bank.4. Positive DC Terminal (red) - the inverter’s connection to thepositive terminal on the battery bank.5. Input Circuit Breaker - this circuit breaker protects the unit’sinternal wiring and pass-thru relay.6. Output Circuit Breaker - this circuit breaker provides anotherlayer of overload protection. Not a branch circuit-rated breaker.Separate AC output breakers may be required on the output.7. Mounting Flanges (x4) - secures the inverter to shelf/wall.8. AC Wiring Compartment - provides access for all AC input andoutput connections on the inverter.9. AC Output Connection - AC knockout for hardwiring ACoutput.10. AC Input Connection - Strain relief clamp for hardwiring ACinput. Strain relief comes with an attached flexible AC input powercord on the MMS1012- G model.11. DC Ground Terminal - this connection is used to tie the exposedchassis of the inverter to the DC grounding system. This terminalaccepts CU/AL conductors from #14 AWG to #6 AWG.12. GFCI Outlet - Ground Fault Circuit Interrupter outlet (with testand reset capability). Only available on MMS1012-G model.41.0 Introduction1 234567810 91112