14Wall mount for cordless cleanerOptional accessoryNOTE:• The screw to mount the holder is not included. Preparea screw which fits with the material to screw into.Attach the wall mount for cordless cleaner to a hardwooden wall, beam or column, where the wall mount forcordless cleaner can be firmly secured. Always be surethat the wall mount for cordless cleaner is securelyattached before hanging the cleaner. (Fig. 36)CAUTION:• Do not hang the cleaner to the wall mount violentlyor hang other appliances than the cleaner.Things to Check Before Asking for Repairs010051NOTE:• Do not attempt to repair cleaner by yourself.To maintain product SAFETY and RELIABILITY, repairs,any other maintenance or adjustment should beperformed by Makita Authorized Service Centers, alwaysusing Makita replacement parts.OPTIONAL ACCESSORIESCAUTION:• These accessories or attachments are recommendedfor use with your Makita tool specified in this manual.The use of any other accessories or attachments mightpresent a risk of injury to persons. Only use accessoryor attachment for its stated purpose.If you need any assistance for more details regardingthese accessories, ask your local Makita Service Center.• Extension wand (Straight pipe)• Nozzle• Nozzle for carpet• Shelf brush• Corner nozzle• Round brush• Flexible hose• Filter• Prefilter• High performance filter• Wall mount for cordless cleaner• Cyclone attachment• Makita genuine battery and chargerNOTE:• Some items in the list may be included in the toolpackage as standard accessories. They may differ fromcountry to country.Cyclone attachment (Fig. 37)About the cyclone attachmentUsing the cleaner with the cyclone attachment installedreduces the amount of dust that enters the capsule, whichhelps to prevent the suction force from weakening. Inaddition, cleaning after use is also simple.CAUTION:• Always be sure that the tool is switched off and thebattery cartridge is removed before carrying outany work on the tool. If the battery cartridge is leftinserted, the cleaner may start unexpectedly and resultin injury.• Clean the mesh filter of the cyclone attachment andthe filters of the cleaner unit when they becomeclogged. Continued use in the clogged condition mayresult in heating or smoke.NOTICE:• When the cyclone attachment is attached, do notuse the cleaner in the horizontal or upward facingcondition. Doing so may cause the mesh filter tobecome clogged.• Always use the cleaner with the filters installed,even when using the cyclone attachment. Using thecleaner without the filters installed may result in amotor malfunction.NOTE:• Check that the cyclone attachment, cleaner, andstraight pipe are locked properly before use.• Empty the dust case of the cyclone attachment and thecapsule of the cleaner when dust has accumulated.Continued use will result in weakened suction force.Disposing of dustWhen dust has accumulated up to the full line of the dustcase, follow the procedure below and dispose of the dust.1. Hold the dust case firmly, press and hold the twobuttons, and remove the dust case. (Fig. 38)2. Dispose of the dust inside the dust case and removeany dust and powder adhered to the surface of themesh filter.3. Insert the dust case all the way until the two buttonslock with a click. (Fig. 39)NOTE:• Check that the cyclone attachment, cleaner, andstraight pipe are all firmly connected before restartingoperation.• If the suction force does not recover even afterdisposing of the dust and cleaning the mesh filter,check whether dust has accumulated in the capsule ofthe cleaner or clogging has occurred.Symptom Area to be investigated Fixing methodWeak suction power• Is capsule full of dust?• Is filter clogged?• Is the battery cartridge discharged?• Empty dust from capsule.• Dust down or wash filter.• Recharge battery.Not working • Is the battery cartridge discharged? • Recharge battery.