76 Part Number STH038 5/12Select only “Ice Machine Settings” file when multiplemachines will be programmed with the same userspecified settings. Select “Export All” if you areinstalling a replacement board.8. Highlight Export ALL or Export Setup, dependingon your requirements, and press the Checkmark.A display of instructions will appear.9. Follow these on-screen instructions to:A. Insert Drive (Insert the flash drive into theUSB port on the ice machine’s control board.)B. Press Check (Press the Checkmark.)C. Wait For Comp (Wait approximately 5 to 10minutes for the download to complete.D. Depending on software version either ExportComplete, Success or the On/Off screen willappear.SAFE OPERATION MODEAllows the ice machine to operate up to 72 hours if theice thickness probe (E19 fault) and/or water levelprobe sensors fail (E20 fault).• When the control board starts the safe mode analert is flashed on the LCD display to notify theend-user they have a production problem.• The control board automatically initiates andmonitors the safe mode. The control willautomatically exit the safe mode if a normal signalis received from the input.• After 72 hours the control board will enter astandby mode and turn offNOTE: The control board needs a five cycle history tooperate safe mode. If five cycles have never beensuccessfully completed the ice machine will shut-off.• Example - The ice machine is a new installationand the water has not been turned on. The icemachine will stop after five cycles with five longfreeze cycles and five water system faults in theevent log.