Part Number 040005626 5/17 39Removal from Service/WinterizationAIR-COOLED MODELS1. Clean and sanitize the ice machine.2. Place the toggle switch in the off position to turnoff the ice machine.3. Turn off the water supply, disconnect and drainthe incoming ice-making water line at the rear ofthe ice machine and drain the water trough.4. Energize the ice machine, wait one minute for thewater inlet valve to open and blow compressed airin both the incoming water and the drain openingsin the rear of the ice machine to remove all water.5. Place the toggle switch in the off position anddisconnect the electric power at the circuitbreaker or the electric service switch.6. Fill spray bottle with sanitizer and spray all interiorfood zone surfaces. Do not rinse and allow to airdry.7. Replace all panels.WATER-COOLED MODELS1. Perform steps 1-6 under “ Air-Cooled Models.”2. Disconnect the incoming water and drain line fromthe water-cooled condenser.3. Energize the ice machine in the freeze cycle. Theincreasing refrigerant pressure will open the waterregulating valve.4. Blow compressed air through the condenser untilno water remains.