4. Raise front of ice machine and position the wood blocks on edge (3 1/2” height). This will allow the top of the vacuum-formedbase to be accessed.5. Place two beads of black silicone sealant (1” in from the edge) on the front and both sides of the vacuum-formed base.6. Remove wood blocks and lower the ice machine onto the vacuum-formed base (check side and back alignment). Push the centerof the vacuum-formed base tight to the ice machine base. Secure the vacuum-formed base to the ice machine water trough withtape. Remove tape after silicone sealant has set.7. Seal the front edge of the base insulation to the bin with white silicone sealant.Install Mylar Strip between Evaporator and BulkheadMylar will cover the joint where the bulkhead attaches to the base. It will extend from the left sidewall past the water inlet fitting.1. Remove screws (right and left side) that secure the evaporator to the bulkhead.2. Remove three screws located between the evaporator and water inlet line. Remove the screw holding the water inlet fitting.3. Determine bin switch wire location and cut a slot in the top edge of the mylar strip (adhesive edge = top).4. Apply silicone sealant at the bin switch wire entrance and the left side corner (4” each direction) where the base and bulkheadmeet.5. Pull evaporator away from bulkhead. Place bottom of mylar strip in sump trough and slip up behind evaporator (align slot cut instep 3 with bin switch wire). Mylar must extend above bottom evaporator mounting screw (approximately 2” abovegasket/bulkhead joint).6. Remove paper backing from mylar. Apply tension to mylar and work toward the ends to eliminate wrinkles, as the tape ispressed to the bulkhead.7. Align evaporator extrusion and bulkhead screw holes; puncture mylar for the bottom screw holes and insert screws. Install allremaining evaporator screws.8. Puncture mylar and insert screws removed in step 2.Bulkhead and Sidewall Insulation1. Remove upper white backing to expose tape surface (do not remove backing below slit at bottom). Slide the insulation down intothe base and then press the insulation against the bulkhead to secure. Insulation must bottom out on the base.2. Repeat step 1 on the left side bulkhead.3. Install insulation behind water dump valve.4. The back panel insulation will rest in a bed of silicone. Apply a continuous bead of black silicone sealant to the base of the icemachine next to the bulkhead wall.8005483Sheet 2 of 306/02/00Insulation must extend allthe way into the base.