Tested in accordance with BS 4856 Part 1.Flow rate 340 ltr/h (75 gal/h).Flow Rate Correction Factors:455 ltr/h (100 gal/h) multiply by 1.06.227 ltr/h (50 gal/h) multiply by 0.96.113 ltr/h (25 gal/h) multiply by 0.85.08 LO-LINE RC & LO-LINE RC Heater Cooler10.0 Technical DataHeating Performance DataModel Fan SpeedHeat Output wattsTemperature Difference °CHeat Output Btu/hTemperature Difference °F3751 4197 4640 5081 5520 59573351 3748 4144 4538 4930 53212921 3268 3613 3956 4298 46392803 3136 3467 3796 4125 44512367 2648 2928 3206 3483 37591922 2150 2377 2603 2828 30521811 2026 2240 2453 2665 28751437 1608 1777 1945 2114 22821098 1228 1357 1486 1617 17431162 1300 1437 1574 1710 1845843 943 1043 1142 1240 1339741 829 916 1003 1090 1176BoostMediumLowBoostMediumLowBoostMediumLowBoostMediumLow19-1514-109-66-412803 14323 15836 17340 18839 2033111436 12783 14144 15488 16826 181599970 11154 12331 13503 14670 158329567 10703 11833 12957 14077 151928080 9039 9993 10943 11889 128316559 7338 8113 8884 9652 104166182 6916 7645 8372 9096 98164904 5486 6066 6642 7216 77883748 4191 4633 5073 5519 59483965 4436 4905 5371 5836 62972877 3218 3558 3896 4233 45682528 2829 3127 3424 3720 401540° 45° 50° 55° 60° 65° 72° 81° 90° 99° 108° 117°Cooling Performance DataNoise LevelsModel Fan SpeedCooling Performance wattsAir-Mean Water Temperature Difference °CCooling Performance Btu/hAir-Mean Water Temperature Difference °F1533 1305 2291 1656 3128 17251464 1203 2187 1511 2987 16321340 1104 2002 1345 2734 14521228 1052 1835 1347 2505 14271032 878 1542 1113 2106 1159877 754 1310 969 1788 1034710 581 1061 770 1448 957600 507 896 639 1223 655499 423 745 535 1018 553496 397 741 526 1012 654391 335 585 429 798 454321 277 480 357 655 383BoostMediumLowBoostMediumLowBoostMediumLowBoostMediumLow19-1514-109-66-45231 4453 7817 5650 10673 58864995 4105 7462 5156 10192 55684572 3767 6831 4589 9328 49544190 3589 6261 4596 8547 48693521 2996 5261 3798 7186 39552992 2573 4470 3306 6101 35282423 1982 3620 2627 4941 32652047 1730 3057 2180 4173 22351703 1443 2542 1825 3473 18871692 1355 2528 1795 3453 22311334 1143 1996 1464 2723 15491095 945 1638 1218 2235 1307Tot. Sens. Tot. Sens. Tot. Sens.15° 20° 25° 27° 36° 45°Tot. Sens. Tot. Sens. Tot. Sens.Tested in accordance with BS 4856 Part 1. Flow rate 340 ltr/h. Relative humidity 50%.Model Sound Pressures at 2.5m (dBA)19-1514-109-66-4Low Medium BoostWeight, Water Content and Motor PowerModel MotorPower (W)WaterContent (l)UnpackedWeight (kg)19-15 80 0.3 7.714-10 62 0.32 9.19-6 35 0.56 12.76-4 35 0.75 15.7Test Pressure 20bar (2MPa) Maximum Working Pressure 10barWater connections 15mm Electrical supply 230V - 50HzApproximate Hydraulic Resistance through Fan ConvectorsLitres/h 6 - 4910514235479 - 69985201219714 - 1012407193247519 - 151670954469776 - 48.985.062.350.459 - 69.855.101.180.9714 - 1012.207.003.200.7519 - 1516.409.404.600.82455340227113mm wg kPaFor latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818