8888888888TRV thermostatic valve and LKD lockshield valve2TRV1/2ANS2TRV RS Remote sensor 2TRV RA Remote adjuster2TRV1/2ANSDCK122TRV1/2ANSFF WACFF 16 WACLKD 16ANTRV head with verticalangle body headTRV head withstraight body headTRV head with invertedangle body headLKD 16ANLKD 16ANFF LACFF LACDAV12DAV12DAV12LKD 16ANFF WAC Wheelhead angle valve & LKD lockshield valveFor best accuracy 2TRV2 head should be in a horizontal positionaway from heat source. Remote Sensor or Adjuster heads are available2 LKD lockshield valves2 Decorative manual angle valvesTRV thermostatic valve & FF LAC Lockshield angle valveFF WAC Wheelhead angle & FFLAC lockshield angle valve.TRV thermostatic valve & Decorative manual angle valveNOTE:See Radiator Range Technical Specificationsfor Mounting Details of Radiators.Copper pipeCopper pipeCopper pipe Copper pipeCopper pipe11Décor Radiator SeriesH11 6, 8, 10 Tube Connection Options MYSON(FF LAC) Valve is set full open and white knob will not turn. Angle only.(FF WAC) Manual valve, white knob can turn to open or close the valve. Angle only.(LKD) Valve has chrome cap that can be removed exposing an adjustment screw to open or close the valve. Angle or straight.(TRV) Valve is a non-electric thermostatic valve that modulates water flow in response to changes in room temperature and closes when settemperature is achieved. NOTE: This valve will not turn on or shut off your heating system. Horizontal angle, vertical angle or straight pattern.(DCK12) Pipe extension with compression fitting and escutcheon for use with the 2TRV1/2ANS valve.(DAV12) Manual valve, adjust flow with Allen wrench. Valve comes with chrome pipe extension with compression fitting and escutcheon.
PreviousNext |