DS2000 03.20.07 Release NotesSoftware Corrections in 03.20.07DS2000 Release Notes 27 ◆ 03.20.07HotlineHotline Keys To Ring Group Or UCD Masters Don’t FunctionSoftware version 03.20.07 does not allow you to program Hotline keys for Ring Group or UCDHunting Group master numbers (e.g., 600-607 and 700-707). Master numbers are not valid Hotlinedestinations. In prior software versions, however, you could make the assignments in #KP UserProgrammable Features but they would not function.IntercomRing Soft Key Shuts Off Talk PathSoftware version 03.20.07 corrects the following problem what would shut off the Intercom talkpath in prior 03.**.** versions:1. Place an Intercom call from one display keyset to another.2. Quickly press the RING soft key.3. The talk path is shut off and the called extension does not ring.IntraMailExternal TransferWhen setting up an External Transfer, at least one of the trunks involved in the transfer must have1003-Tandem Trunk enabled (Y). In software version 03.14.00, External Transfer would workeven if 1003-Tandem Trunks was disabled (N).Long Greetings Cut Off During RecordSoftware version 03.20.07 corrects a problem in prior 03.**.** versions where a Greeting longerthan 16 seconds could be cut off during recording.Make Call And Message Notification Callout May Cause System ResetSoftware version 03.20.07 corrects a problem in prior 03.**.** versions that could cause a systemreset during a Make Call or Message Notification callout to an outside party. Although more preva-lent with T1 trunks providing answer supervision, the reset could also occur with analog trunks.Message Notification Callout Interferes With Subscriber Mailbox OperationSoftware version 03.20.07 corrects the following problem in prior versions 03.10.08 and above:1. Subscriber dials L to listen to a message.2. While listening, a Message Notification callout begins.3. When the notification callout ends, IntraMail immediately hangs up on the subscriber.Outgoing Message Record Problems when CompactFlash Card FullIf a subscriber tries to record an outgoing message (such as a Mailbox Name or an InstructionMenu) while the IntraMail CompactFlash card is full, they will hear an error message warning themthat no space is available. Recording is not allowed. In prior 03.**.** versions, the recording proce-dure was allowed but the outgoing message was not recorded.Remote Logon Prompt Won’t PlayIn software version 03.14.00, the voice prompt “Please enter your mailbox number” would not play