5-6 Procedures after Completion of InstallationInstallation procedure1. Log in to the system as a root user.2. Set the CD-ROM to the DVD-ROM drive to mount.3. Move to the directory where the server management driver is stored, and install by the rpmcommand.# cd /(mount point)/smm_drv/vmware_3.0.2/320Fd/# rpm –ivh *.rpm4. Move to the directory where the package of the NEC ESMPRO Agent is stored, and install by therpm command.# cd /(mount point)/esmpro_sa/4361-01/# rpm -ivh Esmpro-common-*# rpm -ivh Esmpro-type1-*# rpm -ivh Esmpro-ft-*# rpm -ivh Esmpro-Express-*5. Move the current directory to /opt/nec/esmpro_sa/log to run the following commands.# cd /opt/nec/esmpro_sa/log/# sh /(mount point)/esmpro_sa/vmset.sh -l NONE# sh /(mount point)/esmpro_sa/esmcron.sh6. Restart the OS after ejecting the CD-ROM from the oprital disk drive.# sync# rebootThe functions of the installed NEC ESMPRO Agent become enabled after the reboot.TIPS:To report to NEC ESMPRO Manager from NEC ESMPRO Agent, you need toconfigure the settings on reporting method in “Report Setting Function” after thereboot. Refer to the User’s Guide (/doc/esmsa_users.pdf) stored in the CD-ROMfor how to configure the reporting method.