4. Maintenance of Express5800/ft seriesExpress5800/R310e-E4, R320e-E4, R320e-M4, R310f-E4, R320f-E4, R320f-M4 Maintenance Guide (Windows)24Chapter 1 Maintenance4. Maintenance of Express5800/ft seriesExpress5800/ft series (ft server) can be maintained by the following ways: Using NEC ESMPRO Manager for remote maintenance Using the ft server utility on the ft server for local maintenanceTips To start the ft server utility, select menus as follows:Start Screen ○↓ ft server utility(Start All Programs NEC ESMPRO Agent ft server utility)The table below lists the maintenance way (remote or local) of each feature on the components.ComponentMaintenancefeaturesGeneral CPU module PCI module SCSIenclosureBMCFirmwareStart – Remote / Local Remote / Local – –Stop – Remote / Local Remote / Local – –View MTBF information – Remote / Local Remote / Local – –MTBF clear – Remote / Local Remote / Local – –Diagnosis – Remote / Local Remote / Local – –Dump collection – Remote / Local – – –Board switch – Remote / Local – – –BIOS Update – Remote / Local – – –F/W update – – – – LocalQuick dump Local – – – –Auto firmware update Local – – – –Auto module start Local – – – –Remote: Executable by using NEC ESMPRO Manager remotelyLocal: Executable on local server by using ft server utility–: Not supportedTips The server does not support maintenance feature for the components listed below. Internal devicesSCSI adapter under PCI moduleEthernet board under PCI moduleNetwork port of Ethernet board under PCI moduleSCSI enclosure and SCSI slots under the enclosure Optional devicesImportant Consult with your maintenance personnel to use the maintenance features. Perform the following steps before replacing component.1. Clear MTBF information of relevant component.2. Stop the relevant CPU module and PCI module.