E-50Cable ConnectionCommunication ProtocolBaud rate ............................. 38400 bpsData length .......................... 8 bitsParity .................................... No parityStop bit ................................ One bitX on/off ................................ NoneCommunications procedure . Full duplexNOTE: Depending on the equipment, a lower baud rate may be recommendedfor long cable runs.PC Control Codes and Cable ConnectionPC Control CodesFunction Code DataPOWER ON 02H 00H 00H 00H 00H 02HPOWER OFF 02H 01H 00H 00H 00H 03HINPUT SELECT COMPUTER 02H 03H 00H 00H 02H 01H 01H 09HINPUT SELECT COMPONENT 02H 03H 00H 00H 02H 01H 10H 18HINPUT SELECT VIDEO 02H 03H 00H 00H 02H 01H 06H 0EHINPUT SELECT S-VIDEO 02H 03H 00H 00H 02H 01H 0BH 13HINPUT SELECT DVI (DIGITAL) 02H 03H 00H 00H 02H 01H 1AH 22HINPUT SELECT VIEWER 02H 03H 00H 00H 02H 01H 1FH 27HPICTURE MUTE ON 02H 10H 00H 00H 00H 12HPICTURE MUTE OFF 02H 11H 00H 00H 00H 13HSOUND MUTE ON 02H 12H 00H 00H 00H 14HSOUND MUTE OFF 02H 13H 00H 00H 00H 15HON SCREEN MUTE ON 02H 14H 00H 00H 00H 16HON SCREEN MUTE OFF 02H 15H 00H 00H 00H 17HNOTE: Contact your local dealer for a full list of PC Control Codes if needed.NOTE: Pins 2, 3, 5, 6 and 8 are used inside the projector.PC Control Connector (DIN-8P)125 4 3678To RxD of PCTo TxD of PCTo GND of PCUsing Software Keyboard1 to 0 and Characters........................... Use to type in IP address or projector nameSP ...................... Inserts a spaceBS ...................... Deletes one character backward ........................ Returns to the previous ........................ Advances to the nextOK ...................... Executes the selectionCancel ................ Cancels the selectionMODE ................ Selects one of three modes for alphabet and specialcharacters.