(17/43)CR (0Dh): End of packet7.2 Power control1) The controller requests the monitor to control monitor power.HeaderSOH (01h): Start Of Header'0' (30h): ReservedMonitor ID: Specify the Monitor ID which you want to change a setting.Ex.) If Monitor ID is '1', specify 'A'.'0' (30h): Message sender is the controller.'A' (41h): Message type is "Command".'0'-'C (30h, 43h): Message length is 12 bytes.MessageSTX (02h): Start of Message'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control command'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode0001: ON0002, 0003: Do not set.0004: OFF (same as the power off by IR)ETX (03h): End of MessageCheck codeBCC: Block Check CodeRefer to the section 4.5 “Check code” for a BCC calculation.DelimiterCR (0Dh): End of packet2) The monitor replies a data for confirmation.HeaderSOH (01h): Start Of Header'0' (30h): Reserved'0' (30h): Message receiver is the controller.Monitor ID: Indicate a replying Monitor ID.Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.'B' (42h): Message type is "Command reply".'N'-'N': Message lengthNote.) The maximum data length that can be written to the monitor at a time is 32bytes.Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).MessageSTX (02h): Start of Message'0'-'0' (30h, 30h): Result code. No error.'C'-'2’,'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command The monitor replies same as power control command to the controller.'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode0001: ON0002, 0003: Do not set.0004: OFF (same as the power off by IR)ETX (03h): End of MessageCheck codeBCC: Block Check CodeHeader Message Check code DelimiterSOH-'0'-Monitor ID-'0'-'A'-'0'-'C' STX-'C'-'2'-'0'-'3'-'D'-'6'-'0'-'0'-'0'-'1'-ETXBCC CRHeader Message Check ode DelimiterSOH-'0'-'0'-MonitorID-'B'-'0'-'E'STX-'0'-'0'-'C'-'2'-'0'-'3'-'D'-'6'-'0'-'0'-'0'-'1'-ETXBCC CR