EnglishEnglish-26This monitor uses RXD, TXD and GNDlines for RS-232C control.The reverse type cable (null modem cable)should be used for RS-232C control.This Plasma monitor can be controlled via personalcomputer using an RS-232C connection.MONITOR ID and RS-232C CONTROLUp to 26 individual monitors can be controlled through adaisy chain via RS-232C connection.1. Connect PC to the monitor.Connect a PC’s RS-232C control output to the monitor'sRS-232C input. You can then connect theRS-232C output from this monitor to another monitor’sRS-232C input. Up to 26 monitors can be connectedusing RS-232C.2. Set Monitor ID and RS-232C Control mode.For proper operation, the Monitor ID should be setin the OSD menu of each monitor that is in the chain.The Monitor ID can be set under the “OPTION3”menu in the OSD. The Monitor ID number can be setwithin a range from 1 to 26 or set to "ALL". No twomonitors should share the same Monitor ID number.It is recommended to number each monitor in a daisychain sequentially from 1. The fi rst monitor in the daisychain is designated as the primary monitor. Subsequentmonitors with the chain are secondary monitors.In the “OPTION3” menu on the first monitor in theRS-232C daisy chain set the "RS232C CONTROL" to"NORMAL". Set the "RS232C CONTROL" to “2ND”on all other monitors.Functions that can be controlled via RS-232C:Powering ON or OFFSwitching input signalsNOTE: If your PC (IBM or IBM compatible) is equippedonly with a 25-pin serial port connector, a 25-pinserial port adapter is required. Contact your dealerfor details.NOTE: In order to function, the RS-232C OUT terminalcan only be connected to another monitor of thesame model. Do not connect to other types ofequipment.••RS-232CEXIT MUTEINPUT EXIT MUTEINPUTPC(Out)RS-232C Cable RS-232C CableRS-232C (IN) RS-232C (OUT)INOUTINOUTRS-232C (IN) RS-232C (OUT)