13W415-0763 / 03.04.10NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE. THE HIGHERTEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO COMBUSTIBLECHASE MATERIALS TO CAUSE A FIRE.DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE.TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDING THEPROVISION OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE. TOPROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE WEATHER, WERECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST-RESISTANT PAINT.DO NOT FILL ANY FRAMED SPACE AROUND THE CHIMNEY WITH INSULATION OR ANY OTHER MATERIAL.INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TO OVERHEAT.MAINTAIN A MINIMUM 2" AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM AT ALL TIMES.FAILURE TO MAINTAIN THIS 2" AIR CLEARANCE WILL CAUSE A STRUCTURE FIRE. NEVER FILL THISSPACE WITH ANY TYPE OF MATERIAL.DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP, STORM COLLAR ANDTERMINATION CAP ARE PACKAGED WITH THESE PARTS.DO NOT CUT RAFTERS OR CEILING JOISTS WITHOUT FIRST CONSULTING A BUILDING OFFICIALTO ENSURE STRUCTURAL INTEGRITY IS NOT COMPROMISED.FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOOR AREA.THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHTABOVE THE STOVE. ALL HORIZONTAL SMOKE PIPE MUST SLOPE SLIGHTLY UPWARDS A MINIMUMOF 1/4” PER FOOT AND ALL CONNECTIONS MUST BE TIGHT AND SECURED BY THREE SHEETMETAL SCREWS EQUALLY SPACED. AN UNINSULATED SMOKE PIPE SHALL NOT PASS THROUGHAN ATTIC, ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR THROUGH A FLOOR,CEILING, WALL OR PARTITION, OR ANY COMBUSTIBLE CONSTRUCTIONS.DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION.! WARNING4.1 CHIMNEYYour appliance may be connected to a factory built or masonry chimney. If you are using a factory builtchimney, it must comply with ULCS629 (Canada) or UL103 HT (USA) standards. It must therefore be a 6" HTType (2100°F) chimney. Use only specified components with no substitutions. It is extremely important thatit be installed according to the manufacturer's specifications. The manufacturer's installation instructions andspecified clearances should always be followed in accordance with local and national codes. In Canada theCSA B365 and the CSA C22.1 installation codes are to be followed. In the USA the ANSI NFPA 70 and ANSINFPA 211 installation codes are to be followed.Chimney and chimney connector must be in good condition and kept clean.