13W415-0763 / B / 10.28.11! WARNINGNEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE.THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TOCOMBUSTIBLE CHASE MATERIALS TO CAUSE FIRE.DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE.TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDINGTHE PROVISIONS OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE.TO PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THEWEATHER, WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST RESISTANT PAINT.DO NOT FILL ANY FRAMED SPACE AROUND THE CHIMNEY WITH INSULATION OR ANY OTHERMATERIAL INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TOOVERHEAT.MAINTAIN A MINIMUM 2” AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM AT ALLTIMES. FAILURE TO MAINTAIN THIS 2” AIR CLEARANCE WILL CAUSE A STRUCTURE FIRE. NEVERFILL THIS SPACE WITH ANY TYPE OF MATERIAL.DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP, STORM COLLAR ANDTERMINATION CAP ARE PACKAGED WITH THESE PARTS.DO NOT CUT RAFTERS OR CEILING JOISTS WITHOUT FIRST CONSULTING A BUILDING OFFICIALTO ENSURE STRUCTURAL INTEGRITY IS NOT COMPROMISED.FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOORAREA.THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHTABOVE THE STOVE. ALL HORIZONTAL SMOKE PIPE MUST SLOPE SLIGHTLY UPWARDS AMINIMUM OF 1/4” PER FOOT AND ALL CONNECTIONS MUST BE TIGHT AND SECURED BY THREESHEET METAL SCREWS EQUALLY SPACED. AN UNINSULATED SMOKE PIPE SHALL NOT PASSTHROUGH AN ATTIC, ROOF SPACE, CLOSET, OR SIMILAR CONCEALED SPACE, OR THROUGH AFLOOR, CEILING, WALL OR PARTITION, OR ANY COMBUSTIBLE CONSTRUCTION.DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION.63.84.1 CHIMNEYYour appliance may be connected to a factory built or masonry chimney. If you are using a factory builtchimney, it must comply with ULCS629 (Canada) or UL103 HT (USA) standards. It must therefore be a 6" HTType (2100°F) chimney. Use only specified components with no substitutions. It is extremely important thatit be installed according to the manufacturer's specifications. The manufacturer's installation instructions andspecified clearances should always be followed in accordance with local and national codes. In Canada theCSA B365 and the CSA C22.1 installation codes are to be followed. In the USA the ANSI NFPA 70 and ANSINFPA 211 installation codes are to be followed.Chimney and chimney connector must be in good condition and kept clean.