8W415-0763 / B / 10.28.112.5 RATING PLATE INFORMATIONFor rating plate location, see“INSTALLATION OVERVIEW”section.This illustration is for referenceonly. Refer to the rating plateon the appliance for accurateinformation.1400 SERIES RATING PLATE ILLUSTRATEDSAMPLELISTED SOLID FUEL BURNING FIREPLACE INSERT /ENCASTRÉ À COMBUSTIBLE SOLIDE HOMOLOGUÉTESTED TO / TESTÉ SELON :ULC S628 / UL 1482FROM HEATER / DU POÊLERESIDENTIAL / RÉSIDENTIEL140012IN/PO (305 mm)12IN/PO (305 mm)6IN/PO (150 mm)USING DOUBLE WALL CONNECTOR / UTILISATIOND’UN CONDUIT DE RACCORDEMENT ÀDOUBLE PAROIMAISON / MOBILE HOME*1400 140010IN/PO (254 mm) 10IN/PO (254 mm)6IN/PO (152 mm) 6IN/PO (152 mm)4IN/PO (102 mm) 4IN/PO (102 mm)EPI 1402INSTALL AND USE ONLY INACCORDANCE WITH THEMANUFACTURER’SINSTRUCTIONS AND LOCALBUILDING CODES.MINIMUM CEILING HEIGHT:7FT (2.13m)HEARTH EXTENSION /COMBUSTIBLE FLOORPROTECTION: IF INSTALLEDON A COMBUSTIBLE FLOOR,UNIT MUST BE PLACED ON ANON-COMBUSTIBLE FLOORPROTECTOR EXTENDING 18”(455mm) IN FRONT AND 8”(205mm) TO THE SIDES ANDBACK.CHIMNEY TYPE: MINIMUM 6”(152mm) DIAMETERAPPROVED RESIDENTIALTYPE FOR MOBILE HOME USEA CHIMNEY LISTED TO ULCS629 IN CANADA OR UL 103HTIN THE USA.CHIMNEY CONNECTOR: 6”(152mm) DIAMETER MINIMUM24 GAUGE STEEL MINIMUMCLEARANCE FROMHORIZONTAL CONNECTORAND CEILING 18” (455mm).DO NOT OBSTRUCT SPACEUNDER HEATER.SPECIAL METHODS AREREQUIRED WHEN PASSING ACHIMNEY THROUGH A WALLOR CEILING. SEE INSTRUC-TIONS AND BUILDING CODES.DO NOT CONNECT THIS UNITTO A CHIMNEY FLUE SERVINGANOTHER APPLIANCE.FUEL: FOR USE WITH WOODONLY. DO NOT USE GRATE ORELEVATE FIRE. BUILD WOODFIRE DIRECTLY ON HEARTH.WARNING: RISK OF SMOKESPILLAGE. OPERATE ONLYWITH DOOR FULLY CLOSED.REPLACE GLASS ONLY WITHCERAMIC GLASS.DO NOT OVERFIRE. IFHEATER OR CHIMNEYCONNECTORS GLOW, YOUARE OVERFIRING. INSPECTAND CLEAN CHIMNEYFREQUENTLY. UNDERCERTAIN CONDITIONS OFUSE CREOSOTE BUILD-UPMAY OCCUR RAPIDLY.OPTIONAL BLOWER KIT:EP-62, 115V, 60HZ, 0.82AMP.ROUTE CORD AWAY FROMUNIT.DANGER: RISK OFELECTRICAL SHOCK.DISCONNECT POWERBEFORE SERVICING UNIT.INSERT: INSTALL AND USEONLY IN SOLID FUELBURNING FIREPLACES. DONOT REMOVE BRICKS ORMORTAR FROM SOLID FUELBURNING FIREPLACE.INSTALL WITH A POSITIVEFLUE CONNECTOR ANDFACEPLATE.POUR INSTALLATION ETUTILISATION CONFORMÉMENT AUXINSTRUCTIONS DU FABRICANT ETAUX CODES LOCAUX DU BÂTIMENT.HAUTEUR DE PLAFOND MINIMAL7PI (2,13m).PROLONGEMENTD’ÂTRE/PROTECTION DUPLANCHER COMBUSTIBLE: SIINSTALLÉ SUR UN PLANCHERCOMBUSTIBLE, L’APPAREIL DOITÊTRE PLACÉ SUR UNE PLAQUEPROTECTRICE INCOMBUSTIBLES’ÉTENDANT SUR 18” (455mm) ÀL’AVANT ET 8” (205mm) À L’ARRIÈREET SUR LES CÔTÉS.TYPE DE CHIMNÉE: DIAMÈTREMINIMAL DE 6” (152mm)APPROUVÉE POUR USAGERÉSIDENTIEL. MAISON MOBILEEMPLOYEZ UNE CHEMINÉEHOMOLOGUÉE ULC S629 AUCANADA OU UL 103HT AUXÉTATS-UNIS.RACCORD DE CHEMINÉE:DIAMÈTRE DE 6” (152mm) D’ACIERDE CALIBRE 24 MINIMUM. 18”(455mm) DE DÉGAGEMENT MINIMALENTRE LE RACCORD HORIZONTALET LE PLAFOND.NE RIEN ENTREPOSER SOUSL’APPAREIL.DES MÉTHODES SPÉCIALES SONTREQUISES LORSQU’UNE CHEMINÉETRAVERSE UN MUR OU UNPLAFOND. VOIR LES INSTRUC-TIONS ET LES CODES DUBÂTIMENT.NE PAS RACCORDER À LACHEMINÉE D’UN AUTRE APPAREIL.COMBUSTIBLE: POUR USAGE AVECLE BOIS SEULEMENT. N’UTILISEZPAS DE CHENET OU NESURÉLEVEZ PAS LE BOIS.PRÉPAREZ LE FEU DIRECTEMENTSUR L’ÂTRE.AVERTISSEMENT: RISQUED’ÉCHAPPEMENT DE FUMÉE. TENIRLA PORTE FERMÉE LORSQUE LEPOÊLE FONCTIONNE. REMPLACEZLA VITRE PAR UNE VITRE ENCÉRAMIQUE SEULEMENT.NE SURCHAUFFEZ PAS L’APPAREIL.SI L’APPAREIL OU LES RACCORDSROUGEOIENT, L’APPAREILSURCHAUFEE. INSPECTEZ ETNETTOYEZ LA CHEMINÉEFRÉQUEMMENT. DANS CERTAINESCONDITIONS, DES DÉPÔTS DECRÉOSOTE PEUVENT SE FORMERRAPIDEMENT.SOUFFLERIE OPTIONNELLE: EP-62,115V, 60HZ, 0,82A. TENEZ LECORDON ÉLECTRIQUE LOIN DEL’APPAREIL.DANGER: RISQUE DE SECOUSSEÉLECTRIQUE. DÉBRANCHEZ AVANTDE PROCÉDER À L’ENTRETIEN.ENCASTRÉ: INSTALLEZ ET UTILISEZSEULEMENT DANS UN FOYER ÀCOMBUSTIBLE SOLIDE. NE RETIREZPAS DE MORTIER, NI BRIQUES DUFOYER À COMBUSTIBLE SOLIDE.INSTALLEZ AVEC UNE GAINECONFORME ET UNE PLAQUE DERECOUVREMENT.CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS ANDINSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USEIN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT). AMINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY BEREQUIRED BY THE AUTHORITY HAVING JURISDICTION.RENSEIGNEZ-VOUS AUPRÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DUSERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONSD’INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTREINSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNEPRISE D’AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm)JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANTJURIDICTION.8" 8"18"8"ALCOVEA"B"CBACK WALL (M/A)45°SIDE WALL (M/L)BACK WALL (M/A)SIDE WALL (M/L)BAIF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BEPLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THATEXTENDS 8” (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18”(455mm) TO THE FRONT.SI LE POÊ LE EST INSTALLÉ SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉSUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSERLES CÔTÉS ET L’AMÉRE DU POÊ LE DE 8” (200mm) ET SE PROLONGER DE 18”(455mm) SUR LE DEVANT.MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALLCHIMNEY CONNECTOR / DÉGAGEMENTS MINIMAUX AUX MATÉRIAUXCOMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:* MODEL 1400 MAY BE INSTALLED INTO A MOBILE HOME IN THE UNITEDSTATES ONLY.* LE MODÈLE 1400 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISONMOBILE AUX ÉTATS-UNIS SEULEMENT.CEILING / PLAFONDCD BAFLOOR / PLANCHERHOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSESKIN BURNS.QUAND L’APPAREIL FONCTIONNE, LA SURFACE DEVIENTCHAUDE. NE PAS TOUCHER. TENIR LES ENFANTS, LESVÊTEMENTS ET LES MEUBLES À L’ÉCART. LE CONTACT PEUTCAUSER DES BRÛLURES À LA PEAU.CAUTION:ATTENTION:W385-0401 / JDATE CODE / DE DATEEPA1400CLEARANCES TO COMBUSTIBLE CONSTRUCTION /D ÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)A SIDE FACING / CÔTÉ 1 IN/PO (25mm)*B TOP FACING / DESSUS 28 IN/PO (710mm)C MANTEL / TABLETTE 28 IN/PO (710mm)D SIDE WALL / MUR LATÉRAL 17 IN/PO (430mm)*CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AUBORD DE LA FAÇADE1400 1400L 1402 1450WOLF STEEL LTD.24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA1400C9700539 (WSL)4001657 (NGZ)4001658 (NAC)4001659 (WUSA)LISTED SOLID FUEL BURNING SPACE HEATER /POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉTESTED TO: / TESTÉ SELON : UL1482 / ULC S627MODEL / MODÈLE - EPA 140015982U.S. Environmental Protection Agency Certified to comply with July 1990, particulate emissions standards/Certifié conforme à la norme d’ émanation de particles de juillet 1990: 40 CFR Part 60, Subpart AAA