25W415-0434 / G / 08.08.114.5 OPTIONAL WALL SWITCH / THERMOSTATFor ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenientlocation. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. Therecommended maximum lead length depends on wire size:WIRE SIZE MAX. LENGTH14 gauge 100 feet16 gauge 60 feet18 gauge 40 feetDisconnect the existing wires from terminals 1 and 3 (from theON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.50.1312! WARNINGDO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110VOLT ELECTRICITY.4.6 MOBILE HOME INSTALLATIONThis appliance is certified to be installed as an OEM (Original Equipment Manufacturer) installation ina manufactured home or mobile home and must be installed in accordance with the manufacturer’sinstructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, inthe United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance isonly for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the mobilehome appliance.29.1This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. Builtin appliances are equipped with 1/4” diameter holes located in the front left and right corners of the base. Use #10hex head screws, inserted through the holes in the base to secure. For free standing products contact your localauthorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must befastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot andthe fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lightingthe appliance, ensure that the logs are positioned correctly.This appliance is certified to be installed in an aftermarket permanently located, manufactured (mobile)home, where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is notconvertible for use with other gases, unless a certified kit is used.Conversion KitsThis appliance is field convertible between Natural Gas (NG) and Propane (LP).To convert from one gas to another consult your Authorized dealer/distributor.