4W415-1071 / C / 01.11.122.1 GENERAL INSTRUCTIONSThoroughly clean the chimney, flue and existingappliance before installing the new appliance intoit. Do not burn solid fuels in any appliance that isequipped with this gas log set.The installation of this appliance must conform withlocal codes or in the absence of local codes, it mustconform to ANSI Z.223.1 or the CAN/CGA B149.Do not operate appliance in the presence of gasolineor other flammable liquids and vapours. Keep areaclear of other combustible materials. The applianceand its shut off must be disconnected from the gas supply piping system before any pressure testing of thesystem is done.Installation practices vary from region to region and it is important to know the specifics that apply to yourarea,For example: in Massachusetts State:• This product must be installed by a licensed plumber or gas fitter when installed within thecommonwealth of Massachusetts.• The appliance damper must be removed or welded in the open position prior to installation of aappliance• insert or gas log.• The appliance off valve must be a “T” handle gas cock.• The flexible connector must not be longer than 36 inches.• The appliance is not approved for installation in a bedroom or bathroom unless the appliance is adirect vent sealed combustion product.• A carbon monoxide detector is required in all rooms containing gas fired appliances.No external electricity (110 volts or 24 volts) is required for the gas system operation.ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,WITH THE GLASS DOOR OPENED OR REMOVED.PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.PROVIDE ADEQUATE VENTILATION.NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THEFRONT FACE OF THE UNIT.SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACTWHEN THE APPLIANCE IS OPERATING.FIRE RISK. EXPLOSION HAZARD.HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GASLINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURETESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTINGCOMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.DO NOT USE A BLOWER INSERT, HEAT EXCHANGER INSERT OR ANY OTHER ACCESSORY NOT APPROVED FOR USEWITH THIS APPLIANCE! WARNINGWe suggest that our gashearth products be installedand serviced by professionalswho are certified in the U.S.by the National FireplaceInstitute® (NFI) as NFI GasSpecialistswww.nficertified.org