W415-2164 / A / 07.21.164EN2.1 DIMENSIONS2.2 GENERAL INSTRUCTIONSThe appliance and its individual shutoff valve must be disconnected from the gas supply piping system duringany pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must beisolated from the gas supply piping system by closing its individual manual shutoff valve during any pressuretesting of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).When the appliance is installed directly on combustible material other than wood flooring, the appliance shallbe installed on a metal or wood panel extending the full width and depth.35 5/8"905mm23"585mm46 11/16"1186mmFRONT VIEW RIGHT SIDE VIEW TOP VIEW36 5/16"922mmTHIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER toconform with local codes. Installation practices vary from region to region and it is important to knowthe specifics that apply to your area, for example inMassachusetts State:• The appliance off valve must be a “T” handle gascock.• The flexible connector must not be longer than 36”(914.4mm).The installation must conform with local codes or, inabsence of local codes, the National Gas and PropaneInstallation Code CSA B149.1 in Canada, or the NationalFuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States.We suggest that our gashearth products be installedand serviced by professionalswho are certified in the U.S.by the National FireplaceInstitute® (NFI) as NFI GasSpecialistswww.nficertified.orgALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,WITH THE GLASS DOOR OPENED OR REMOVED.NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” (1219.2mm)FROM THE FRONT FACE OF THE APPLIANCE.FIRE RISK. EXPLOSION HAZARD.HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TEST-ING GAS LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFOREPRESSURE TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (35mb).USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITHTHIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GASCOMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILLVOID THE WARRANTY AND CERTIFICATION.THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.! WARNINGALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,WITH THE GLASS DOOR OPENED OR REMOVED.NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” (1219.2mm)FROM THE FRONT FACE OF THE APPLIANCE.FIRE RISK. EXPLOSION HAZARD.HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TEST-ING GAS LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFOREPRESSURE TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (35mb).USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITHTHIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GASCOMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILLVOID THE WARRANTY AND CERTIFICATION.THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.! WARNING