35W415-1519 / H / 03.22.17ENTear the embers into pieces and place along the front row of ports covering all of the burner area in front ofthe small logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposededges of the fibre hairs will glow. The ember material will only glow when exposed to direct flame;however, care should be taken to not block the burner ports.Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZERTMlogs glow when exposed to direct flame. Use only certified "glowing embers" and PHAZERTM logs availablefrom your local authorized dealer / distributor.L1 (Black)L2(White)Cable connectorElectrical boxcoverGround(Green)Screw ElectricalboxWire nuts(Black)Ground(Green)(White)3 prongreceptacle! WARNINGDO NOT BLOCK THE BURNER PORTS. BLOCKED PORTS CAN CAUSE AN INCORRECT FLAMEPATTERN, CARBON DEPOSITS AND DELAYED IGNITION.32.1Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner.Fine dust found in the bottom of the bag should not be used.NOTE: Charcoal embers are not to be placed on the burner.! WARNINGDO NOT BLOCK THE BURNER PORTS. BLOCKED PORTS CAN CAUSE AN INCORRECT FLAMEPATTERN, CARBON DEPOSITS AND DELAYED IGNITION.! WARNINGDO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIEDSERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THEELECTRICAL CIRCUIT.RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THEAPPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCEWITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIANELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 INTHE UNITED STATES.ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,WITH THE GLASS DOOR OPENED OR REMOVED.69.2_26.5.1 GLOWING EMBERS6.5.2 CHARCOAL EMBERS7.0 WIRING DIAGRAM7.1 RECEPTACLE WIRING DIAGRAM7.2 ELECTRONIC WIRING DIAGRAM