8W415-1519 / H / 03.22.17EN2.4 RATING PLATE INFORMATIONINSTALLER: It is your responsibility to check off the appropriate box on the rating plate according tothe model, venting and gas type of the appliance.For rating plate location, see “INSTALLATION OVERVIEW” section.This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.NOTE: The rating plate must remain with the appliance at all times. It must not be removed.A barrier designed to reduce the risk of burns from the hot viewing glass is provided with theappliance and must be installed.W385-2070 / ACONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.Page 1 of 2FOYER À GAZ VENTILÉ DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SISON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONSMOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DESECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORMERELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONSDANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. POURUNE UTILISER AVEC BARRIÈRE W565-0144. SUIVEZ LES INSTRUCTIONSD'INSTALLATION SE TROUVENT DANS LE MANUEL D'INSTALLATION.DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOMINSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCEWITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION ANDSAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOTAPPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTUREDHOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. FOR USE WITH BARRIERW565-0144. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.9700539 (WSL) 4001657 (NGZ)4001658 (NAC) 4001659 (WUSA)0-4500FT (0-1370m) ALTITUDE / ELEVATION 0-4500FT (0-1370m)35,000 BTU/h INPUT / ALIMENTATION 32,000 BTU/h21,000 REDUCED INPUT / ALIMENTATION REDUITE 22,000MANIFOLD PRESSURE: 3.5" (9MB) WATER COLUMN MANIFOLD PRESSURE: 10" (25MB) WATER COLUMNPRESSION AU COLLECTEUR: 3.5" (9 MB) D'UNE COLONNE D'EAU PRESSION AU COLLECTEUR: 10" (25MB) D'UNE COLONNE D'EAUMINIMUM SUPPLY PRESSURE: 4.5" (11MB) WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" (27MB) WATER COLUMNPRESSION D'ALIMENTATION MINIMALE: 4.5" (11MB) D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MINIMALE: 11" (27MB) D'UNE COLONNE D'EAUMAXIMUM SUPPLY PRESSURE: 7.0" (17MB) WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13" (32MB) WATER COLUMNPRESSION D'ALIMENTATION MAXIMALE: 7.0" (17MB) D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MAXIMALE: 13" (32MB) D'UNE COLONNE D'EAUP4: 61.3% P4: 69.2%NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOORSCERTIFIED WITH THIS UNIT ONLY.WARNING: THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACEONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. MINIMUM CLEARANCETO COMBUSTIBLE MATERIALS /DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:TOP/ DESSUS 0 RECESSED DEPTH / PROFONDEUR D'ENCASTRE 18"FLOOR / PLANCHER 0 VENT SIDES / COTES DE L'EVENT 2"SIDES / COTES 0 VENT TOP / EVENT SUPERIEUR 3"BACK / ARRIERE 0 VENT BOTTOM / EVENT INFERIEUR 2"MANTEL / MANTEAU 10 1/2 ”* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTIONMANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DESEXTENSIONS PLUS GRANDES.SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURSD'EVACUATION MINIMALE ET MAXIMALE.WOLF STEEL LTD.24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADAUN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CETAPPAREIL. UTILISER AVEC LES PORTES VITREES HOMOLOGUEESSEULEMENT AVEC CETTE UNITE.AVERTISSEMENT: CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE.REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE.N’AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMESAUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERSINSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING ISNECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL ESTIMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DUSYSTEME DE PRISE D'AIR.DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCEPRODUIT DÉCORATIF: NE PAS UTILISER COMME APPPAREIL DE CHAUFFAGE.ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZOPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: EP35SERIAL NUMBER/NO. DE SERIE: GX70MATERIAL: .010 VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTERMIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI. " TO BE 10 POINT ARIAL, BOLD FACE,UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT. HOLE TO BE 0.250” Ø.BLACK ON WHITE BACKGROUNDMAX OVERALL DECAL SIZE: 4.75" x 8.50"HOLE IS 0.250” Ø / 0.312 “FROM BOTTOM AND LEFT EDGE”SERIAL NUMBERS TO BE ASCENDING FROM GX70 194150TITLE: RATING PLATE GX70(N,P)T(E), CX70(N,P)T(E)REVISION: A UPDATED BTU RATING || 09.03.15 TBDWG#: W385-2070DATE: 07.14.15_R.TGX70NT CX70NT MODEL GX70PT CX70PTGX70NTE CX70NTE MODEL GX70PTE CX70PTEASAMPLEWARNING: Allow appliance to cool before performing any maintenance or cleaning.Both the rating plate and lighting instructions are attached to a chain located on the left side of the controlarea near the valve.