W415-2197 / B / 08.28.18EN8general information1.2 rating plate informationThis illustration is for reference only. Refer to the rating plate on the appliance for accurate information..The rating plate must remain with the appliance at all times. It must not be removed.note:MAX SIZE: 8.5" X 4.75"HOLE TO BE 0.250"Ø / 0.312” FROM EDGESMATERIAL: CLASS III A-2, PERMANENT LABEL, WATERPROOF, 0.010 IN. VELVET MATTE LEXAN AND/OR 0.050 IN. HI-TEMP POLYESTER, CAPABLE OF WITHSTANDING A MAXIMUMTEMPERATURE OF 175°F (79°C).MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "NE CONVIENT PAS AUX COMBUSTIBLES SOLIDES. " TO BE 10 POINT VOGUE, BOLD FACE, UPPER CASE AND 2POINT LEADING SPACING OR EQUIVALENT.BLACK LETTERING ON WHITE BACKGROUND.SERIAL NUMBERS TO BE ASCENDING FROM HD35 024057Certified to Canadian and American National Standards: CSA 2.22-2016 / ANSI Z21.50-2016 for Vented Decorative Gas AppliancesCertifié selon les normes Nationales Canadiennes et Américaines: CSA 2.22-2016 / ANSI Z21.50-2016 pour les Appareils à gaz décoratif à évacuationDirect vent, vented gas fireplace. Approved for bedroom, bathroom and bed-sitting room installation. Suitable for mobile home installation, if installed in accordance with the current standard CAN / CSAZ240MH Series gas equipped mobile homes in Canada, or, in the United States, the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. When this US Standard is notapplicable, use the Standard for Fire Safety Criteria for Manufactured Home Installations, Sites and Communities, ANSI / NFPA 501A. This appliance must be installed in accordance with local codes, ifany; if none, follow the current ANSI Z223.1 or CSA B149. When installed with screen kit GD-565KT, the appliance complies with CGA certification requirement CR95-006. For use with barrierW565-0211. Follow installation instructions.Foyer à gaz ventilé. Homologué pour installation dans une chambre à coucher, une salle de bain et un studio. Approprié pour installation dans une maison mobile si son installation conforme aux exigencesde la norme CAN / CSA Z240MH Séries de maisons mobile équipées au gaz en vigueur au Canada, ou, aux États-Unis selon la norme 24 CFR, Part 3280, Manufactured Home Construction and SafetyStandard. Dans le cas ou cette norme d’États-Unis n’est pas pertinentes, utiliser la norme NFPA 501A, Fire Safety Criteria for Manufactured Home Installations, Sites and Communities. Installer l’appareilselon les codes ou règlements locaux ou, en l’absence de tels règlements, selon les codes d’installation ANSI Z223.1 ou CSA B149 en vigueur. Lorsqu’il est installé avec le pare-étincelles GD-565KT,l’appareil se conforme à la norme l’ACG CR95-006. Utiliser uniquement avec l’écran W565-0211. Suivre les instructions d’installation.9700539 (WSL) 4001658 (NAC) 4001657 (NGZ) 4001659 (WUSA)HD35NT CHD35NT HD35PT CHD35PTMODEL / MODÈLEAltitudeInputReduced InputP4ÉlévationAlimentationAlimentation RéduiteP4Manifold Pressure: 3.5” w.c. (NG)Minimum Supply Pressure: 4.5” w.c. (NG)Maximum Supply Pressure: 7”* w.c. (NG)Pression au Collecteur: 3,5” d’une colonne d’eau (GN)Pression d’Alimentation Min.: 4,5” d’une colonne d’eau (GN)Pression d’Alimentation Max.: 7”* d’une colonne d’eau (GN)*Maximum inlet pressure not to exceed 13”.Manifold Pressure: 10” w.c. (P)Minimum Supply Pressure: 11” w.c. (P)Maximum Supply Pressure: 13” w.c. (P)Pression au Collecteur: 10” d’une colonne d’eau (P)Pression d’Alimentation Min.: 11” d’une colonne d’eau (P)Pression d’Alimentation Max.: 13” d’une colonne d’eau (P)*Pression d’alimentation maximale ne devait pas dépasser 13”.0-4500ft (0-1370m)25,000 BTU/h17,500 BTU/h61.3%Minimum clearance to combustible materials:Top 0”Floor 0”Sides 0”Back 0”Vent top 2”Vent sides & bottom 1”Mantel 13”**Dégagements minimaux des matériaux combustibles:Dessus 0”Plancher 0”Côtés 0”Arrière 0”Dessus du conduit d’évent 2”Côtés et dessous du conduit d’évent 1”Tablette 13”**Recessed depth 21 7/8” Profondeur d’encastré 21 7/8”**Maximum horizontal extension: 2”. See installation manual forgreater extensions, minimum vent lengths and maximum ventlengths.**L’extension horizontale maximale: 2”. Référez au manueld’installation pour des extensions plus grandes, les longueursd’évacuation minimaux et maximum.Serial Number / N° de Série:W385-2104 / BTITLE: LABEL, RATING PLATE (C)HD35NT / (C)HD35PT (SB)REVISION: B: Updated P4 efficiency + safety barrier part number + added energy efficiency label || 08.13.18_DWG#: W385-2104DATE: 09.04.15WOLF STEEL LTD.REFERENCE# 161746HD35VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCEOF HEAT, NOT INTENDED FOR USE AS A HEATINGAPPLIANCE, NOT FOR USE WITH SOLID FUEL.APPAREIL À GAZ DÉCORATIF À ÉVACUATION: N’EST PASUNE SOURCE DE CHALEUR; N’EST PAS DESTINÉ À ÈTREUTILISÉ COMME UN APPAREIL DE CHAUFFAGE; NECONVIENT PAS AUX COMBUSTIBLES SOLIDES.FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY.POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRECERTIFIÉES AVEC L’APPAREIL.WARNING : Do not add any material to the appliance which will come in contact with theflames, other than that supplied by the manufacturer with the appliance.AVERTISSEMENT: N’ajoutez pas à cet appareil aucun matériau devant entretiencontact avec les flammes autre que celui qui est fourni avec cet appareil par le fabricant.The appliance must be vented using the appropriate Napoleon vent kits. See installationmanual for venting specifications. Proper reinstallation and resealing is necessary after servicingthe vent-air intake system.L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez aumanuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller etresceller l’évacuation après avoir executer l’entretien du système de prise d’air.Optional fan kit: GZ550-1KTEnsemble de ventilateur facultatif: GZ550-1KTElectrical rating: 115V, 60HZ. Less than 12 amperes.Spécifications électriques: 115V, 60HZ. Moins de 12 ampère.BBBBWOLF STEEL USA103 Miller Drive,Crittenden, Kentucky, USA, 41030WOLF STEEL LTD.24 Napoleon Rd. Barrie,Ontario L4M 0G8 CanadaPAGE 1 OF 2B1.3 mobile home installationThis appliance must be installed in accordance with the manufacturer’s instructions and the ManufacturedHome Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile HomeStandard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gasindicated on the rating plate.This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Builtin appliances are equipped with 1/4” (6.4mm) diameter holes located in the front left and right corners of the base.Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact yourlocal authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance mustbe fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot andthe fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting theappliance, ensure that the logs are positioned correctly.This appliance is certified to be installed in an aftermarket permanently located, manufactured (mobile) home,where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertiblefor use with other gases, unless a certified kit is used.Conversion KitsThis appliance is field convertible between Natural Gas (NG) and Propane (P).To convert from one gas to another, consult your Authorized dealer/distributor.20.1note:Conversion kits are not available for Vent Free appliances.SAMPLEBuilt in appliances are equipped with 1/4” (6.4mm) diameter holes located in the front left and right corners of thebase, Use #10 hex head screws, inserted through the holes in the base to secure. For free standing productscontact your local authorized dealer / distributor for the appropriate securing kit. For mobile home installations,the appliance must be fastened in place. It is recommended that the appliance be secured in all installations.Always turn off the pilot and the fuel supply at the source, prior to moving the mobile home. After moving themobile home and prior to lighting the appliance, ensure that the logs are positioned correctly.