W415-1501 / E / 12.17.18EN155.0 installation! WARNING• Never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this singlewall pipe may radiate sufficient heat to combustible chase materials to cause a fi re.• To avoid danger of fi re, all instructions must be strictly followed, incluidng the provision of air space clearancebetween chimney system and enclosure. To protect against the effects of erosion on those parts exposed tothe weather, we recommend that the chase top be painted with a rust-resistant paint.• Maintain a minimum 2" (51mm) air clearance to all parts of the chimney system at all times. Failure to maintainthis 2" (51mm) air clearance will cause a structure fi re.• Detailed instructions for installation of the chase top, storm collar, and termination cap are packaged with theseparts.• Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.• The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year, and asrequired.A raised hearth, together with the appliance built on a raised platform, is recommended for easier wood loadingand fire viewing.5.1 chimneyANCHOR PLATEANCHOR PLATE GASKETAPPLIANCE TOPANCHOR PLATE FOR A FACTORYBUILT CHIMNEYThis appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards. This appliance hasmet the test criteria for Zero Clearance Installation to Combustible Surfaces and Certified to burn fi rewood only.Any chimney listed to the following standards; CAN/ULC-S604 and CAN/ULC-S629 for Canada or UL-103 or UL-103HT for the United States may be installed.Installation of all types of factory-built chimney systems is to be inaccordance with the chimney manufacturers installation instructions.An appropriate chimney manufacturers anchor base plate and anchorbase plate gasket is required in order to initiate their system. Usethe high temperature gasket, supplied, to seal between the anchorplate and the appliance top. Air cooled chimney systems are notrecommended in colder climates.For complete installation instructions, refer to instructions provided withthe manufactured chimney system.A chimney venting the appliance shall not vent any other appliance. The minimum overall chimney height fromthe top of the appliance is 15ft (4.6m). The maximum overall chimney height from the top of the appliance is 34ft(10.4m).Factory-built chimney systems for use in dwellings constructed for three or more families must be enclosedabove the room in which the appliance is located. This enclosure must have a fire resistance rating equal to orgreater than that of the fl oor or roof assembly through which they pass.The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA.Ensure that minimum clearances are maintained.Portions of the chimney that extend through accessible spaces must always be encased to avoid personalcontact with the chimney and thereby avoid damage to the chimney.The chimney must be supported at a maximum of 20ft (6.1m) intervals. Every 20 ft (6.1m) of chimney can weighup to approximately 200lbs (90.7kg).note:All venting connections must be in compliance with the chimney manufacturer’s installation instructions.note:Use only the chimney diameter specified on the rating plate of theappliance.