W415-1596 / 11.25.1524ENCOMBUSTIBLE FRAMING:Sides, back, bottom of theappliance0” to stand-offsCOMBUSTIBLE FINISHING:Sides 2” (51mm) to front edge of the applianceEnclosure Top 84” (2134mm) from the bottom of the applianceRecessed Depth 22 1/4” (565mm)Sides of the vent pipe 2” (51mm)*Bottom of the vent pipe 1” (25mm)Top of vent pipe 2” (51mm)*Ceiling 70” (1778mm) from the bottom of the appliance* HORIZONTAL VENT SECTIONS: A minimum clearance of 1” (25mm) at the bottom and 2” (51mm) at the topand sides of the vent pipe in all horizontal runs to combustibles is required except for clearances in applianceenclosures. Horizontal vent sections within enclosures require a minimum clearance of 18” (457mm) at thetop of the vent pipe. See “MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES” section. Use firestopspacer W010-1800 (supplied) where vent pipe penetrates combustible walls.* VERTICAL VENT SECTIONS: A minimum clearance of 1” (25mm) all around the vent pipe on all verticalruns to combustibles is required except for clearances in appliance enclosures. Vertical vent sectionswithin enclosures require a minimum clearance of 4” (102mm) to the sides of the vent pipe. See “MINIMUMCLEARANCE TO COMBUSTIBLE ENCLOSURES” section. Use firestop spacer W500-0367 (not supplied)where vent pipe penetrates combustible ceilings or floors.5.1 MINIMUM CLEARANCE TO COMBUSTIBLES22 1/4"565mm40 3/4" 1035mm22 1/4"565mm40 3/4" 1035mm40 3/4" 1035mm35 1/4"895mm47"1094mm16 9/16"421mm66 1/2" 1689mmBACK WALL OF CHASE / ENCLOSURE(INCLUDING ANY FINSIHING MATERIALS)2" 51mm2" 51mm4" 102mm4" 102mm 6" 152mmINSIDECHASEOUTSIDECHASE