Appendix A SpecificationsNI PXIe-8130 User Manual A-4 ni.comShock and VibrationOperating Shock .....................................30 g peak, half-sine, 11 ms pulse(Tested in accordance withIEC-60068-2-27. MeetsMIL-PRF-28800F Class 2 limits.)Random VibrationOperating .........................................5 to 500 Hz, 0.3 grms(with solid-state hard drive)Nonoperating ...................................5 to 500 Hz, 2.4 grms(Tested in accordance withIEC-60068-2-64. Nonoperatingtest profile exceeds therequirements ofMIL-PRF-28800F, Class 3.)Note Specifications are subject to change without notice.SafetyThis product is designed to meet the requirements of the followingstandards of safety for electrical equipment for measurement, control,and laboratory use:• IEC 61010-1, EN-61010-1• UL 61010-1, CSA 61010-1Note For UL and other safety certifications, refer to the product label or visitni.com/certification, search by model number or product line, and click theappropriate link in the Certification column.Electromagnetic CompatibilityThis product is designed to meet the requirements of the followingstandards of EMC for electrical equipment for measurement, control,and laboratory use:• EN 61326 EMC requirements; Minimum Immunity• EN 55011 Emissions; Group 1, Class A• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class ANote For EMC compliance, operate this device according to product documentation.