GV60 TROUBLESHOOTING MANUAL RESPONDING TO ALARMSPAGE 4.1.4 VERSION 1.0 2018-01-01Identifying an AlarmYou can identify an alarm locally by viewing the local or remote AUI’s Transmitter Status page (see“AUI Transmitter Status Page Checks”). As a backup option, you can also view the front panel of thecontroller module (A4) (see “Controller Module Front Panel Alarm Checks” on page 4.1.7).AUI Transmitter Status Page ChecksIf an alarm exists and is being recognized by the transmitter (i.e., the Status button at the bottom ofthe AUI display will be red), it is displayed on the transmitter status page (see Figure 4.1.1 on page4.1.5). The Device name indicates the sub-system origin of the alarm. The sub-systems that can bedisplayed are: Controller: All alarms in this sub-system apply to the controller. Exciter A or B: All alarms in this sub-system apply to an exciter (A or B). Rack #: All alarms in this sub-system apply to a rack (cabinet) (6 for GV60). RF Module #: All alarms in this sub-system apply to a specific RF power module (1 through 24)